Surface Tension by Image Analysis: Fast and Automatic Measurements of Pendant and Sessile Drops and Bubbles

✍ Scribed by F.K. Hansen


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
502 KB
Volume
160
Category
Article
ISSN
0021-9797

No coin nor oath required. For personal study only.

✦ Synopsis


New developments in the method of axisymmetric drop shape analysis by image analysis have reduced the computational requirements of this method to the PC level. In this work, an edge detection procedure that gives sub-pixel resolution is combined with general interpolation and smoothing techniques into a PC program that is able to measure pendant and sessile drops and bubbles in typically 5 seconds. To obtain good initial estimates for the shape parameter, (\beta), and size parameter, (\boldsymbol{R}_{0}), of a drop, two alternative methods are used, dependent on the drop's contact angle with the horizontal plane. These methods employ polynomial expressions determined from theoretical profiles. A second order optimization procedure gives a minimized residual of 0.1 to 0.4 pixel units in (1-2) runs. The surface tension of water was determined by both pendant and sessile drops and sessile bubbles, and gave satisfactorily consistent results. A major source of error in sessile drop measurements was found to be uneven wetting of the substrate, leading to lack of axisymmetry. ΰΉ‘ 1993 Academic Press, Inc.


πŸ“œ SIMILAR VOLUMES


Surface Elasticity and Viscosity from Os
✍ Rolf Myrvold; Finn Knut Hansen πŸ“‚ Article πŸ“… 1998 πŸ› Elsevier Science 🌐 English βš– 175 KB

The pendant drop/sessile drop instrument developed by our group and based on video image analysis has been enhanced to measure oscillating drops and bubbles at a rate up to 25 pictures per second. Data analysis has been developed to analyze the results from sinusoidal oscillations in terms of dilata

Measurement of the Surface and Interfaci
✍ Rok Gunde; Arun Kumar; Stefanie Lehnert-Batar; Roland MΓ€der; Erich J. Windhab πŸ“‚ Article πŸ“… 2001 πŸ› Elsevier Science 🌐 English βš– 124 KB

Described herein is a two-phase nonempirical method for the determination of surface or interfacial tension of stationary systems that also allows the determination of drop correction factor. The method is based on the theoretical calculation of the drop profile associated with the maximum volume of

Axisymmetric Drop Shape Analysis: Comput
✍ O.I.del Rı́o; A.W. Neumann πŸ“‚ Article πŸ“… 1997 πŸ› Elsevier Science 🌐 English βš– 209 KB

## Numerous methodologies have been developed for the State-of-the-art axisymmetric drop shape analysis (ADSA) measurement of interfacial tensions and contact angles, techniques for the computation of interfacial tensions and contact as outlined in Refs. ( 8,9 ) . Of these, axisymmetric drop angle

A Study of the Measurement of Surface an
✍ Bingyin Pu; Donghao Chen πŸ“‚ Article πŸ“… 2001 πŸ› Elsevier Science 🌐 English βš– 66 KB πŸ‘ 1 views

The maximum liquid drop volume (v(max)) is measured by using a back-suction micrometer syringe piston technique. Different very viscous liquids are measured by (v(max)) and (v(f)) methods to observe the effect of viscosity on tension measurement. No apparent viscosity effect was observed in surface