𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Surface damage analysis of retrieved highly crosslinked polyethylene tibial components after short-term implantation

✍ Scribed by B. M. Willie; L. J. Foot; M. W. Prall; R. D. Bloebaum


Book ID
102297738
Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
189 KB
Volume
85B
Category
Article
ISSN
1552-4973

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The use of highly crosslinked polyethylene (PE) in the knee remains controversial, because of reduced fatigue fracture properties of the material. The current study investigated postmelt surface damage as well as potential contributors to this damage in retrieved highly crosslinked PE tibial components, after short‐term in vivo durations. Retrieved conventional PE tibial components were examined for comparison, as well as unused time zero highly crosslinked and conventional PE tibial components for inherent manufacturing surface characterization. Predominant surface damage modes on highly crosslinked PE components were machine mark loss and abrasion, while conventional PE components primarily had machine mark loss, abrasion, and delamination. In vivo duration, PE thickness, and conformity of the design were significant predictors of surface damage on retrieved conventional PE components. Donor weight and the conformity of the design were significant predictors of surface damage on retrieved highly crosslinked PE components. This retrieval data on highly crosslinked PE tibial components suggest that in vivo wear occurred, observed as postmelt surface damage. The highly crosslinked Durasul material examined in this retrieval study appeared to outperform the conventional PE components made from 4150 resin, ram‐extruded and γ‐sterilized in air, but not the conventional components made from 1020 resin, compression molding and γ sterilization in nitrogen. Early retrieval data of highly crosslinked PE tibial components are important to serve as a benchmark to be compared with future longer‐term retrieval studies investigating whether surface damage translates to clinically relevant particulate wear debris generation and PE clinical performance. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008


📜 SIMILAR VOLUMES


Examining the influence of short-term im
✍ B. M. Willie; L. J. Foot; M. W. Prall; R. D. Bloebaum 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 123 KB

## Abstract Concerns remain regarding the oxidative resistance of highly crosslinked polyethylene (PE). The study investigated the __in vivo__ performance of Durasul highly crosslinked PE by comparing the oxidation index, density, and percent crystallinity in the weightbearing and nonweightbearing