𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Superselective pseudocontinuous arterial spin labeling

✍ Scribed by Michael Helle; David G. Norris; Susanne Rüfer; Karsten Alfke; Olav Jansen; Matthias J. P. van Osch


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
482 KB
Volume
64
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A new technique for the imaging of flow territories of individual extra‐ and intracranial arteries is presented. The method is based on balanced pseudocontinuous arterial spin labeling but employs additional time‐varying gradients in between the radiofrequency pulses of the long labeling train. The direction of the additional gradient vector is perpendicular to the selected artery and its azimuthal angle is switched after every radiofrequency pulse. The phases of the radiofrequency pulses are adopted to cancel out the phase accrual of the spins at the center of the target vessel due to the extra applied gradients. This results in efficient inversion at the targeted position, whereas elsewhere time‐varying phase changes will result in marginal inversion efficiency. By changing the moment of the added gradients, the size of the labeling focus can be adjusted. Influence of the temporal order of the additional gradients on the labeling efficiency and on the selectivity was investigated by simulations and experimental measurements. In a volunteer study, the acquisition of high signal‐to‐noise ratio flow territory images of small branches of the anterior cerebral artery distal to the circle of Willis was demonstrated. This shows the method's flexibility for dealing with complicated arterial geometries and its ability to superselectively label small intracranial arteries. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Vessel-encoded arterial spin-labeling us
✍ Eric C. Wong 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 474 KB

## Abstract A new signal‐to‐noise ratio (SNR) efficient method is introduced for the mapping of vascular territories based on pseudocontinuous arterial spin labeling (ASL). A pseudocontinuous tagging pulse train is modified using additional transverse gradient pulses and phase cycling to place some

Quantifying CBF with arterial spin label
✍ Richard B. Buxton 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 121 KB

## Abstract The basic principles of measuring cerebral blood flow (CBF) using arterial spin labeling (ASL) are reviewed. The measurement is modeled by treating the ASL method as a magnetic resonance imaging (MRI) version of a microsphere study, rather than a diffusible tracer study. This approach,

Perfusion analysis using dynamic arteria
✍ Emmanuel L. Barbier; Afonso C. Silva; Hyung J. Kim; Donald S. Williams; Alan P. 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 266 KB

A variety of magnetic resonance (MR) techniques have proved useful to quantify perfusion using endogenous water as a blood flow tracer. Assuming that water is a freely diffusable tracer, the model used for these techniques predicts that the quantitation of perfusion is based on three parameters, all

Arterial spin labeling: Validity testing
✍ James R. Ewing; Yue Cao; Robert A. Knight; Joseph D. Fenstermacher 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 147 KB

## Abstract Arterial spin labeling (ASL) is a potential means of obtaining quantitative images of cerebral blood flow (CBF). However, few validation studies of ASL have been performed in animal models using gold‐standard CBF methods. Other methods that use radiolabeled water as a tracer underestima

Perfusion imaging using dynamic arterial
✍ Emmanuel L. Barbier; Afonso C. Silva; Seong-Gi Kim; Alan P. Koretsky 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 224 KB

Recently, a technique based on arterial spin labeling, called dynamic arterial spin labeling (DASL (Magn Reson Med 1999;41:299-308)), has been introduced to measure simultaneously the transit time of the labeled blood from the labeling plane to the exchange site, the longitudinal relaxation time of