𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Superparamagnetic Iron Oxide Hepatic MR Imaging: Efficacy and Safety Using Conventional and Fast Spin-Echo Pulse Sequences

✍ Scribed by Lawrence H. Schwartz; Steven E. Seltzer; Clare M. C. Tempany; Stuart G. Silverman; David R. Piwnica-Worms; Douglass F. Adams; Lee Herman; Lisa A. Herman; Roshann Hooshmand


Publisher
John Wiley and Sons
Year
1995
Tongue
English
Weight
628 KB
Volume
5
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The purpose of this study was to evaluate the technical efficacy and safety of iv ferumozldes (Feridex^a^), a superparamagnetic iron oxide contrast agent for detection of hepatic lesions using conventional spin‐echo and fast spin‐echo MR images. Precontract and postcontrast MR studies were performed on 25 patients with suspected focal hepatic lesions. Conventional Tl‐and T2‐weighted MR images, as well as fast spin‐echo and fat suppressed fast spin‐echo MR images, were evaluated. Quantitative assessment of the contrast agent was performed obtaining region of interest measurements of the liver, spleen, and selected hepatic lesions. The pulse sequences were also evaluated subjectively for overall image quality and a subjective assessment of lesion detection. The use of a superparamagnetic iron oxide contrast agent led to a decrease in hepatic signal intensity on all pulse sequences. Lesion‐to‐liver contrast increased 41.1%, 36.5%, and 32.0% on the conventional T2, fast spin‐echo, and fat suppressed fast spin echo pulse sequences, respectively. Lesion‐to‐liver contrast decreased on the T1‐weighted postcontrast pulse sequence by 23.8%. Despite Improvement in lesion‐to‐liver contrast, radiologists subjectively preferred the precontract sequences because of overall better image quality. At a dose of 10 μmol/kg, fenunoxides favorably impacts lesion‐to‐liver contrast, and may be useful in hepatic imaging, more with conventional T2‐weighted spin‐echo pulse sequences than with T2‐weighted fast spin‐echo pulse sequences.


📜 SIMILAR VOLUMES


Evaluation of intraportal venous flow di
✍ Katsuyoshi Ito; Ayame Shimizu; Toshinobu Tsukuda; Katsumi Sasaki; Masahiro Tanab 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 414 KB

## Abstract ## Purpose To evaluate the efficacy of subtracted MR images from two sets of unenhanced three‐dimensional (3D) MR angiography data (tag‐on and tag‐off images) acquired simultaneously during a single breath‐hold in assessing the intraportal venous flow distribution to the distal branche