Radiofrequency magnetron sputter deposition was used to deposit Ca-P sputter coatings on titanium discs, and these coatings were implanted subcutaneously into the backs of rabbits. Half of the as-sputtered coatings were subjected to additional heat treatment for 2 h at 500Β°C. X-ray diffraction (XRD)
Subperiosteal implantation of various RF magnetron sputtered Ca-P coatings in goats
β Scribed by Wolke, J. G. C. ;de Groot, K. ;Jansen, J. A.
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 243 KB
- Volume
- 43
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
The aim of this study was to obtain more information about the initial biological events around RF magnetron sputtered calcium phosphate (Ca-P) coatings. Therefore, uncoated and coated disks were inserted subperiosteal into the tibia of a goat. The coatings were deposited on commercially pure titanium. The thickness of the coating was 0.1 or 2.0 mm. All the as-sputtered coatings were subjected to an additional heat treatment for 2 h at 500ΠC. After 1 and 3 weeks of implantation the experimental disks were retrieved and prepared for histological and physicochemical analysis. The histological results demonstrated that the periosteum covered the specimens after both implantation periods. In between the periosteum and implant an acellular layer and a collagen matrix was observed. Energy dispersive spectrometry revealed that the acellular layer consisted of C, Ca, and P ions for the 0.1 mm thick Ca-P coatings. The 2 mm thick Ca-P coatings also showed the presence of sulfate ions in this layer. Only organic material was found on the titanium disks. Further, SEM showed that even after 3-week implantation, a substantial thickness of both coatings was still maintained. Thin film X-ray diffraction demonstrated that after both implantation periods, the CaP-0.1 coating was still present. FTIR of the retrieved specimens demonstrated on the coated disks the formation of additional carbonate apatite (CO 3 -AP) associated with an organic phase (NH 2 groups). On basis of these findings we conclude that our experimental approach is very suitable for the investigation of the healing process around Ca-P coatings. Further, we again demonstrated that the initial interfacial response to Ca-P materials differs from titanium.
π SIMILAR VOLUMES
The aim of this study was to investigate the bone response to calcium phosphate (Ca-P) plasma-spray and radiofrequency magnetron sputter-coated implants with comparable roughness. Therefore, tapered conical screw designed implants were installed in the trabecular bone of the femurs of nine goats. Th
The response of bone of low density to uncoated, fluorapatite 6-month implantation periods. In addition, probably due to (FA), hydroxyapatite (HA), and hydroxyapatite heat treated the wide inter-and intra-animal variability, no significant (HAHT) plasma-sprayed coated implants was investigated diffe
Various studies already have shown that the occurrence of oral implant failure is higher in the maxilla than in the mandible. To learn whether Ca-P coatings can improve the success rate of oral implants in the maxilla, three different plasma-sprayed, Ca-P-coated, self-tapping BrΓ₯nemark implants were