Resistive Plate Chambers operated in streamer mode have been chosen as trigger detectors for the forward dimuon spectrometer of the ALICE experiment. During tests performed at CERN PS, small size prototypes with low-resistivity bakelite electrodes and with a strongly quenched gas mixture have shown
Study of resistive plate chambers for the alice dimuon spectrometer
β Scribed by R. Arnaldi; A. Baldit; N. Bastid; G. Blanchard; E. Chiavassa; P. Cortese; G. Dellacasa; N. De Marco; P. Dupieux; B. Espagnon; J. Fargeix; M. Gallio; L. Luquin; F. Manso; V. Metivier; A. Musso; A. Piccotti; A. Rahmani; V. Ramillen; O. Roig; L. Royer; E. Scomparin; C. Soave; E. Vercellin
- Publisher
- Elsevier Science
- Year
- 1999
- Tongue
- English
- Weight
- 411 KB
- Volume
- 78
- Category
- Article
- ISSN
- 0920-5632
No coin nor oath required. For personal study only.
β¦ Synopsis
The trigger system of the Alice dimuon spectrometer is based on RPC detectors. We present experimental results of a beam test about rate capability, time resolution and cluster size of single gap RPC detectors operating both in 'streamer mode' and in 'avalanche mode'. We have compared the performances of small chambers (50x50 cm 2) built with bakelite of different resistivity, from ,,-3.109 f2cm to ,-, 3. 1011 ~2cm. For the low resistivity RPC we obtained a rate capability of several hundreds of Hz/cm 2 when it is operating in 'streamer mode', and of several thousands of Hz/cm 2 when it is operating in 'avalanche mode'.
π SIMILAR VOLUMES
The EEE (Extreme Energy Events) Project, conceived by its leader Antonino Zichichi, is an experiment to study very high-energetic air showers (EAS) through the detection of the shower's muon component using a network of tracking detectors, installed in Italian high schools. The single tracking teles
A kind of multi-gap resistive plate chamber (MRPC) was developed for the STAR experiment at RHIC. The MRPC has excellent time resolution with high efficiency and can be used as the time-of-flight detector. In this paper, we present some performance of MRPC tested by cosmic ray, and performances of M