Structured illumination microscopy of autofluorescent aggregations in human tissue

✍ Scribed by Gerrit Best; Roman Amberger; David Baddeley; Thomas Ach; Stefan Dithmar; Rainer Heintzmann; Christoph Cremer


Book ID
104057705
Publisher
Elsevier Science
Year
2011
Tongue
English
Weight
367 KB
Volume
42
Category
Article
ISSN
0968-4328

No coin nor oath required. For personal study only.

✦ Synopsis


Sections from human eye tissue were analyzed with Structured Illumination Microscopy (SIM) using a specially designed microscope setup. In this microscope the structured illumination was generated with a Twyman-Green Interferometer. This SIM technique allowed us to acquire light-optical images of autofluorophore distributions in the tissue with previously unmatched optical resolution. In this work the unique setup of the microscope made possible the application of SIM with three different excitation wavelengths (488, 568 and 647 nm), thus enabling us to gather spectral information about the autofluorescence signal.


πŸ“œ SIMILAR VOLUMES


Spatial calibration of structured illumi
✍ Grace S. Lee; Lino F. Miele; Aslihan Turhan; Miao Lin; Dusan Hanidziar; Moritz A πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 420 KB

## Abstract Quantitative assessment of microvascular structure is relevant to the investigations of ischemic injury, reparative angiogenesis and tumor revascularization. In light microscopy applications, thick tissue specimens are necessary to characterize microvascular networks; however, thick tis

Hyperspectral imaging microscopy for ide
✍ Silas J. Leavesley; Naga Annamdevula; John Boni; Samantha Stocker; Kristin Grant πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 936 KB

## Abstract Standard fluorescence microscopy approaches rely on measurements at single excitation and emission bands to identify specific fluorophores and the setting of thresholds to quantify fluorophore intensity. This is often insufficient to reliably resolve and quantify fluorescent labels in t

Analysis of structural changes in normal
✍ S. Rubin; F. Bonnier; C. Sandt; L. VentΓ©o; M. Pluot; B. Baehrel; M. Manfait; G. πŸ“‚ Article πŸ“… 2008 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 310 KB πŸ‘ 2 views

## Abstract Aortic aneurisms are frequently asymptomatic but can induce dramatic complications. The diagnosis is only based on the aortic diameter and not on a structural and compositional basis. In this preliminary study, we propose infrared microspectroscopy to nondestructively probe normal and a