𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Structure and process quality illustrated by fibreoptic intubation: analysis of 1612 cases

✍ Scribed by T. Heidegger; H. J. Gerig; B. Ulrich; T. W. Schnider


Book ID
104456986
Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
98 KB
Volume
58
Category
Article
ISSN
0003-2409

No coin nor oath required. For personal study only.

✦ Synopsis


Summary

The purpose of this investigation was the description of structure and process quality based on the analysis of 1612 fibreoptic intubations. We evaluated all fibreoptic intubations (nasotracheal in awake patients and orotracheal in anaesthetised patients) from a previously described database over a period of 2 years. We assessed structure quality by evaluating the distribution of the fibreoptic intubations across all staff anaesthetists, and process quality by analysing the number of attempts, the time required, the cases where we had to switch to conventional intubation and the complications. In all, 955 nasotracheal and 657 orotracheal intubations were evaluated. Almost all anaesthetists performed at least 15 nasotracheal and 10 orotracheal intubations. The success rate was 85.2% at the first attempt. Within 3 min, 93.9% of all fibreoptic intubations were successfully completed. In 24 cases, fibreoptic intubation was abandoned. Severe nasal bleeding as a major complication occurred in 1.3% of the nasotracheal intubations.