𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Stress MR imaging for evaluation of popliteal artery entrapment

✍ Scribed by Ernesto Di Cesare; Luca Marsili; Giovanni Marino; Carlo Masciocchi; Giuseppe Morettini; Carlo Spartera; Luciano Lupattelli; Roberto Passariello


Publisher
John Wiley and Sons
Year
1994
Tongue
English
Weight
918 KB
Volume
4
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The popliteal artery entrapment (PAE) syndrome has been recognized as a cause of arterial occlusion in young people. It is the result of an anomaly of the relationship between the popliteal artery and the gastrocnemius muscle. Eight young healthy volunteers (16 legs) and six patients (10 legs) with suspected PAE underwent magnetic resonance (MR) imaging. Gradient‐echo images were obtained in axial planes with the leg at rest and during active plantar flexion against resistance. Imaging at rest allowed identification of PAE signs in only one leg, which had an anomalous medial course of the popliteal artery. In the other cases, only the stress technique was able to show signal loss in the popliteal artery due to muscular compression (two legs) or the presence of accessory muscle slip around the vessel (two legs), as confirmed at surgery. MR imaging is therefore a useful technique for the diagnosis of PAE because of its capability of combining information obtainable with other modalities.


📜 SIMILAR VOLUMES


Whole-body MR imaging for the evaluation
✍ Elisa C. Ferreira; Cecília C.B. Brito; Roberto C. Domingues; Marcio Bernardes; E 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 185 KB

## Abstract This paper is a detailed case study of a seven‐year‐old girl who developed precocious puberty. The young girl experienced bilateral breast enlargement, vaginal discharge, and multiple areas of “cafe‐au‐lait” pigmentation on the skin. The skeletal radiographs showed multiple bone lesions

Comparison of MR and PET imaging for the
✍ Ming Yang; Diego R. Martin; Nevzat Karabulut; Mathis P. Frick 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 352 KB

## Purpose: To compare the accuracy of fluoro-18-deoxyglucose positron emission tomography (fdg-pet) and dynamic-enhanced magnetic resonance imaging (mri) scans in the diagnosis of liver metastatic lesions from colon and other sources. ## Materials and methods: Thirty consecutive patients with kn

Evaluation of hepatocyte-specific parama
✍ Akihiro Tanimoto; Burkhard P. Kreft; Yuji Baba; Longhai Zhao; J. Paul Finn; Caro 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 953 KB

## Abstract The hepatocyte‐specific paramagnetic magnetic resonance (MR) contrast agents manganese‐DPDP [__N__,__N__′‐dipyridoxylethylenediamine‐__N__,__N__′‐diacetate 5,5′ bis‐(phosphate)] and gadobenate dimeglumine were used for diagnosing chemically induced hepatitis in rats. Ex vivo liver tissu