๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Stopped-flow kinetic spectrophotometric method for the simultaneous determination of iron, titanium and vanadium

โœ Scribed by Jianhuan Wang; Ronghuan He


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
436 KB
Volume
276
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

โœฆ Synopsis


A kinetic method for the simultaneous determination of iron, titanium and vanadium is proposed based on their inductive effects on the chromium(VI)-iodide-starch reaction in weakly acidic medium. The reaction was monitored with the stopped-flow spectrophotometric technique. The calibration graphs are linear in the ranges O-2.2,0-3.1 and O-l.8 pg ml-' for Fe(II), Ti(II1) and V(IV), respectively, and the detection limits are 0.012, 0.020 and 0.018 pg ml-', respectively. It was found that lOO-loo0 times higher concentrations of Co'+, Ni*+, Zr4+, Mn'+, Cd'+, Cu2+, Pb2+ and tervalent rare earths ions do not interfere with the determination. The method was applied to the determination of Fe, Ti and V in an aluminium alloy and a synthetic sample.