𝔖 Bobbio Scriptorium
✦   LIBER   ✦

STOCHASTIC SEISMIC PERFORMANCE EVALUATION OF TUNED LIQUID COLUMN DAMPERS

✍ Scribed by WON, A. Y. J.; PIRES, J. A.; HAROUN, M. A.


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
972 KB
Volume
25
Category
Article
ISSN
0098-8847

No coin nor oath required. For personal study only.

✦ Synopsis


The seismic performance of Tuned Liquid Column Dampers (TLCDs) for the passive control of flexible structures is investigated using random vibration analysis. A non-stationary stochastic process with frequency and amplitude modulation is used to represent the earthquake strong motion, and a simple equivalent linearization technique is used to account for the non-linear damping force in the TLCD. The governing equations of motion for the structure TLCD system are formulated and reduced to a first-order state vector equation, from which the differential equation for the system response covariance matrix is obtained. The TLCD performance is evaluated on the basis of selected structural response statistics, namely, the expected maximum and root-mean-square displacements, and root-mean-square absolute accelerations and interstorey shears. A parametric study and sensitivity analysis are conducted to assess the TLCD performance and identify critical design parameters. Illustrative examples are presented using SDOF and MDOF shear-beam structural models, a wide-banded stationary random base acceleration and two non-stationary random input ground motions representative of long-and short-duration ground accelerations with significant low-frequency content.


πŸ“œ SIMILAR VOLUMES


Single- and multiple-tuned liquid column
✍ Sadek, Fahim; Mohraz, Bijan; Lew, H. S. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 372 KB πŸ‘ 1 views

Design parameters for single-and multiple-tuned liquid column dampers for reducing the response of structures to seismic excitations are presented. A deterministic analysis is carried out using 72 earthquake ground motion records to determine the tuning ratio, tube width to liquid length ratio, and

Multiple-tuned liquid column dampers for
✍ K. M. Shum; Y. L. Xu πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 466 KB πŸ‘ 1 views

## Abstract This paper presents an experimental investigation on the performance of multiple‐tuned liquid column dampers (MTLCD) for reducing torsional vibration of structures in comparison with single‐tuned liquid column dampers (STLCD). A large structure model simulating its torsional vibration a

Experimental evaluation on seismic perfo
✍ Hsu, H.-L.; Lin, J.-L. πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 425 KB πŸ‘ 1 views

This paper presents experimental information on the behaviour of sandwich box columns subjected to combined bending and axial loading. The sandwich box columns consisted of double thin-walled steel tubes with concrete between them. Owing to the interaction between steel and concrete, the composite m