Stir bar sorptive extraction for the analysis of short-chain chlorinated paraffins in water
✍ Scribed by Julio Llorca-Porcel; Esther Martínez-Soriano; Ignacio Valor
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 310 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
An optimised method using stir bar sorptive extraction (SBSE) and a thermal desorption‐GC‐electron capture detector (GC‐ECD) for the determination of short‐chain chlorinated paraffins from water samples was developed. Recoveries near to 100% were obtained by using 20 mm×0.5 mm (length×film thickness) PDMS commercial stir bars from 200 mL spiked water samples and 20% methanol addition with an extraction period of 24 h. Method sensitivity, linearity and precision were evaluated for surface water and wastewater spiked samples. A LOD of 0.03 and 0.04 μg/L was calculated for surface and wastewater, respectively. The precision of the method given as an RSD was below 20% for both matrices. The developed method was applied for the analysis of two real samples from a contaminated river and a wastewater treatment plant. Results were in accordance with those obtained using a previously developed method based on solid phase microextraction (SPME).
📜 SIMILAR VOLUMES
## Abstract Stir bar sorptive extraction‐liquid desorption (SBSE‐LD) has been applied as an efficient sample preparation method for the analysis of beer bitter acids. Extracts free of almost all interfering compounds were obtained, allowing simultaneous analysis of iso‐α‐acids and reduced iso‐α‐aci
## Abstract In this article, a novel polydimethylsiloxane/activated carbon (PDMS‐ACB) material is proposed as a new polymeric phase for stir bar sorptive extraction (SBSE). The PDMS‐ACB stir bar, assembled using a simple Teflon^®^/glass capillary mold, demonstrated remarkable stability and resistan
## Abstract Stir‐bar sorptive extraction and liquid desorption followed by large volume injection‐gas chromatography coupled to mass spectrometry under selected ion monitoring mode acquisition (SBSE‐LD/LVI‐GC‐MS(SIM)) was applied for the determination of six benzotriazole UV stabilizers (Tinuvin P,
## Abstract A sensitive and reproducible stir bar sorptive extraction and HPLC‐UV detection method was used for the therapeutic drug monitoring of chlorpromazine and trifluoperazine in human serum. The separation was achieved using a C~18~ column. The mobile phase consisted of methanol/sodium aceta