𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Stereotactic imaging of the pallidal target

✍ Scribed by Hidehiro Hirabayashi; Magnus Tengvar; Marwan I. Hariz


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
188 KB
Volume
17
Category
Article
ISSN
0885-3185

No coin nor oath required. For personal study only.

✦ Synopsis


In 48 consecutive patients, we applied a new stereotactic imaging technique to individually visualize the pallidal target before surgery. A turbo spin-echo proton density sequence (acquisition time, 6 minutes 5 seconds) was used for 2-mm-thick contiguous axial scanning. Pallidocapsular border, medial putaminal border, and optic tract were visualized bilaterally in all patients. Boundaries of globus pallidus internus, globus pallidus externus, and lamina medullaris interna were clearly visualised in 71% of the patients. The anatomic target point was chosen in the middle of the visualized posteroventral pallidum, irrespective of the position of this point in relation to commissures. The lateralities of pallidocapsular border, lamina medullaris interna, and medial boundary of putamen were measured bilaterally in each patient, and the width of the posteroventral pallidum was assessed. The laterality of structures (measured from a point 2 mm anterior to midcommissural point and at a level 2-4 mm below anterior commissure-posterior commissure line) showed a wide range. The position of the pallidocapsular border varied by up to almost 1 cm between the most medial and the most lateral one. There were also variations in the position of the pallidal structures between left and right hemispheres in the same patients. The posteroventral pallidum was slightly more wide on the left than the right side. Given the significant inter- and intra-individual variabilities of the position of pallidal structures, it may be hazardous to rely solely on the atlas and the commissures for targeting. A magnetic resonance imaging sequence that enables visualization in each individual patient of the target area and its surroundings may contribute to less electrode passes during intraoperative physiological exploration and to more exact location of the lesion or chronic electrode in the posteroventral pallidum.


πŸ“œ SIMILAR VOLUMES


Cortically evoked responses of human pal
✍ Hiroki Nishibayashi; Mitsuhiro Ogura; Koji Kakishita; Satoshi Tanaka; Yoshihisa πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 348 KB

## Abstract Responses of neurons in the globus pallidus (GP) to cortical stimulation were recorded for the first time in humans. We performed microelectrode recordings of GP neurons in 10 Parkinson's disease (PD) patients and 1 cervical dystonia (CD) patient during surgeries to implant bilateral de

The atypical subthalamic nucleusβ€”An anat
✍ RenΓ© Reese; Markus O. Pinsker; Jan Herzog; Fritz Wodarg; Frank Steigerwald; Moni πŸ“‚ Article πŸ“… 2012 πŸ› John Wiley and Sons 🌐 English βš– 309 KB

## Abstract ## Background: The improvement of PD motor symptoms by DBS of the STN depends on exact targeting. ## Methods: A combination of MRI and multitrajectory microrecordings was used for localization of the STN in a group of 228 consecutive PD patients. ## Results: In 1% of our cases, the

Stereotactic image-guided navigation in
✍ W. M. Rozen; M. W. Ashton; D. L. Stella; T. J. Phillips; G. I. Taylor πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 297 KB πŸ‘ 1 views

## Abstract Preoperative imaging is sought prior to DIEA (Deep Inferior Epigastric Artery) perforator flaps due to the potential for maximizing operative success and minimizing operative complications. Recent advances include the use of computed tomography (CT) angiography (CTA) and magnetic resona

Target-point combination of MR images
✍ Richard B. Buxton; Fred Greensite πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 814 KB

## Abstract A method is described for combining multiple magnetic resonance images of the same anatomic slice to produce a single image which incorporates the favorable contrast features of each of the original images. The target‐point method is a general method that includes linear combination as