✦ Synopsis


Diffusion coefficients for water in high permeability ionomers are determined from steady state permeation measurements, corrected for boundary layer resistance and change in vapor concentration along sample length, to circumvent problems due to heat of condensation and structural relaxation. Values for water in the perfluoroionomer, Nafion, converted to solvent self-diffusion coefficients, D 1 , are consistent with the NMR based free volume (fv) relation for Nafion at high concentrations. At low concentrations D 1 decreases more rapidly than fv values, an effect attributed to ion hydration involving up to 6 water molecules per sulfonate group. The reduction in D 1 due to concentration averaging in permeation, estimated using the fv relation, is about 23%. Water vapor sorption isotherms and steady state values of D 1 , for two different types of styrene hydrogenated butadiene triblock ionomers and Nafion can be superimposed using morphology dependent vertical scaling factors. The simple correspondence between results for the hydrocarbon ionomers and Nafion, is attributed to a common transport mechanism based on the restriction of water to ionic pathways. There are a number of claims in the literature that water uptake by highly permeability polymers is greater from the liquid phase than from saturated vapor at unit activity. This paper demonstrates that the disparity, known as Schroeder's paradox, does not occur in sorption under equilibrium conditions or in permeability measurements, if proper corrections for boundary layer resistance and vapor concentration profile are applied.


πŸ“œ SIMILAR VOLUMES


Steady state transport function analysis
✍ R. Jordinson; Susan Arnold; B. Hinde; G.F. Miller; J.G. Rodger; A.H. Kitchin πŸ“‚ Article πŸ“… 1976 πŸ› Elsevier Science 🌐 English βš– 820 KB

Indicator dilution curves recorded downstream following single injections of indicators are widely used for measurement of cardiac output. For injections of a constant amount of the indicator the area under the primary time-concentration curve is inversely proportional to volume flow. The shape of t

Non-steady-state transport of diffusants
✍ Graham J. Le Poidevin πŸ“‚ Article πŸ“… 1982 πŸ› John Wiley and Sons 🌐 English βš– 669 KB

## Abstract Equations describing transient diffusion in ternary laminate slabs are presented. The equations developed can be applied to: (I) asymmetric ABC slabs separating two semi‐infinite baths, each bath containing either the same or different concentration(s) of permeant; (II) asymmetric ABC s