We have performed a calorimetric measurement of the AC loss in a Cable-in-Conduit (CIC) conductor for the superconductive magnetic energy storage (SMES) application. A new technique is used based on the temperature rise in the He II in contact with the conductor. The sample is located in a cryostat
Stability measurements on the 50 kA SMES conductor
โ Scribed by M.J. Pfotenhauer
- Book ID
- 107746250
- Publisher
- Elsevier Science
- Year
- 1991
- Tongue
- English
- Weight
- 531 KB
- Volume
- 31
- Category
- Article
- ISSN
- 0011-2275
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
A method is described for the measurement of ac losses in a cylindrical conductor forming part of a coaxial superconducting pair. Results given for 25 l~n niobium are substantially lower than previous values obtained for this material when tested in the form of narrow strips, and show that, if used
The stability of the conductor against local heat pulses was measured as a function of magnetic field, transport current, temperature and cooling conditions. Comparing liquid helium cooling at 1 bar and supercritical cooling at 4 bar, the stability was found to be higher in liquid helium for transpo