The 'H-and "C-n.m.r. spectra of seven in&lo1 methyl ethers were recorded and assigned. They were classified into five types, and the effect of 0methyl&ion on the chemical shifts of each type is discussed. NOTE ADDED IN PROOF Type F, not encountered in our work, occurs in 1,6-anhydro-3-O-methyl-& D
Spontaneous N → O acyl shift in the [M + H]+ ions of [MeBmt1]-cyclosporins in an ion trap
✍ Scribed by Alexandr Jegorov; Vladimír Havlíček
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 179 KB
- Volume
- 36
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.163
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
In an ion trap the protonated molecules of the cyclic undecapeptides cyclosporins having 3‐hydroxy‐4‐methyl‐2‐methylamino‐6‐octenoic acid (MeBmt) in their backbone undergo an N → O peptidyl shift into the corresponding [M + H]^+^ ions of isocyclosporins. This rearrangement does not take place in cyclosporins [Bmt^1^]Cs and [3′‐deoxy‐MeBmt^1^]Cs. In cyclosporin [Thr^2^]Cs having two threonines in the molecule, only one of them participates in the N,O‐acyl transfer. It can be concluded that the presence of the basic N‐methylamino group of MeBmt, which can serve as the primary site of protonation, is necessary for isocyclosporin formation. A dominating ion series originating from the primary cleavage between MeBmt (first position in the cyclosporin ring) and amino acid residue at the neighbouring eleventh position is then observed in collision‐induced dissociation spectra of protonated molecules of cyclosporins. This ‘isocyclosporin’ ion series can effectively be used for easy and complete cyclosporin sequencing using a tandem mass spectrometric (MS^3^) experiment in an ion trap. The paper further introduces an improved Gross mass spectral nomenclature for cyclic peptide sequencing and several techniques for the generation of protonated molecules of cyclosporins. Their preparation represents the fundamental requirement for smooth sequencing of cyclosporins by tandem mass spectral techniques. Copyright © 2001 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract In a previous report we showed that certain binary Ag^+^–amino acid complexes formed adduct ions by the attachment of a single water and methanol molecule when stored in an ion trap mass spectrometer: complexes with aliphatic amino acids and with 4‐fluorophenylalanine formed the adduct
## A selected ion flow tube (SIFT) experimental investigation has been carried out of the reactions of H 3 O , NO and O 2 with NO, NO 2 , N 2 O and HNO 2 , in order to obtain the essential kinetic data for the analyses of these compounds in air using selected ion flow tube mass spectrometry (SIFT-M