Spin-echo micro-MRI of trabecular bone using improved 3D fast large-angle spin-echo (FLASE)

✍ Scribed by J.F. Magland; M.J. Wald; F.W. Wehrli


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
489 KB
Volume
61
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Fast large‐angle spin echo (FLASE) is a common pulse sequence designed for quantitative imaging of trabecular bone (TB) microarchitecture. However, imperfections in the nonselective phase‐reversal pulse render it prone to stimulated echo artifacts. The problem is further exacerbated at isotropic resolution. Here, a substantially improved RF‐spoiled FLASE sequence (sp‐FLASE) is described and its performance is illustrated with data at 1.5T and 3T. Additional enhancements include navigator echoes for translational motion sensing applied in a slice parallel to the imaging slab. Whereas recent work suggests the use of fully‐balanced FLASE (b‐FLASE) to be advantageous from a signal‐to‐noise ratio (SNR) point of view, evidence is provided here that the greater robustness of sp‐FLASE may outweigh the benefits of the minor SNR gain of b‐FLASE for the target application of TB imaging in the distal extremities, sites of exclusively fatty marrow. Results are supported by a theoretical Bloch equation analysis and the pulse sequence dependence of the effective T~2~ of triglyceride protons. Last, sp‐FLASE images are shown to provide detailed and reproducible visual depiction of trabecular networks in three dimensions at both anisotropic (137 × 137 × 410 μm^3^) and isotropic (160 × 160 × 160 μm^3^) resolutions in the human distal tibia in vivo. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Fast 3D large-angle spin-echo imaging (3
✍ Jingfei Ma; Felix W. Wehrli; Hee Kwon Song 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 881 KB

## Abstract A rapid steady‐state 3D spin‐echo imaging pulse sequence, based on the principle of nutating the spins by an angle greater than 90°, has been designed and implemented on a clinical 1.5‐T whole‐body MR scanner. The pulse sequence, denoted fast large‐angle spin‐echo (FLASE), has been opti

Fast Low-Angle Dual Spin-Echo (FLADE): A
✍ J. Magland; B. Vasilic; F. W. Wehrli 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 704 KB

## Abstract Mechanical strength and fracture resistance of trabecular bone (TB) are largely determined by the structural arrangement of individual trabeculae. Fast 3D spin‐echo approaches are preferable to gradient echoes in that they are less sensitive to local induced gradients at the bone/marrow

Improved blood suppression in three-dime
✍ Mahender K. Makhijani; Houchun H. Hu; Gerry M. Pohost; Krishna S. Nayak 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 469 KB

## Abstract ## Purpose: To provide improved blood suppression in three‐dimensional inner‐volume fast spin‐echo (3D IV‐FSE) carotid vessel wall imaging by using a hybrid preparation consisting of double inversion‐recovery (DIR) and diffusion sensitizing gradients (DSG). ## Materials and Methods: