𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Spectrally resolved pressure dependence measurements of air fluorescence emission with AIRFLY

✍ Scribed by M. Ave; M. Bohacova; B. Buonomo; N. Busca; L. Cazon; S.D. Chemerisov; M.E. Conde; R.A. Crowell; P. Di Carlo; C. Di Giulio; M. Doubrava; A. Esposito; P. Facal; F.J. Franchini; J. Hörandel; M. Hrabovsky; M. Iarlori; T.E. Kasprzyk; B. Keilhauer; H. Klages; M. Kleifges; S. Kuhlmann; G. Mazzitelli; L. Nozka; A. Obermeier; M. Palatka; S. Petrera; P. Privitera; J. Ridky; V. Rizi; G. Rodriguez; F. Salamida; P. Schovanek; H. Spinka; E. Strazzeri; A. Ulrich; Z.M. Yusof; V. Vacek; P. Valente; V. Verzi; T. Waldenmaier


Publisher
Elsevier Science
Year
2008
Tongue
English
Weight
316 KB
Volume
597
Category
Article
ISSN
0168-9002

No coin nor oath required. For personal study only.

✦ Synopsis


The knowledge of the fluorescence emission as a function of atmospheric parameters is essential for the detection of extensive air showers with the fluorescence technique. In this paper, we summarize AIRFLY published measurements of the pressure dependence of the fluorescence yield. The spectral distribution of the fluorescent light between 280 and 429 nm has been measured with high resolution. Relative intensities of 34 spectral lines have been determined. The pressure dependence of 25 lines was measured in terms of quenching reference pressures p 0 l in air. This set of AIRFLY measurements yields the most comprehensive parametrization of the pressure dependence of the fluorescent spectrum.