𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Sonourethrography in the evaluation of anterior urethral strictures: Correlation with radiographic urethrography

✍ Scribed by Sanjay Gupta; Banibrata Majumdar; Ashutosh Tiwari; Rakesh Kumar Gupta; Anant Kumar; Ratni B. Gujral


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
829 KB
Volume
21
Category
Article
ISSN
0091-2751

No coin nor oath required. For personal study only.

✦ Synopsis


A total of 30 patients with suspected urethral strictures underwent sonographic and roentgenographic urethrograms. Two patients showed a normal anterior urethra in the sonourethrogram; 29 strictures were diagnosed in the remaining 28 pa- tients, l patient showing strictures at two different sites. Sonourethrography was an accurate predictor of stricture length, retrograde urethrography underestimating the stricture length in most of the cases. Periurethral structures, including the urethral wall, corpus spongiosum, corpora cavernosa, bulb, and external urinary sphincter, were seen clearly with sonourethrography. Periurethral fibrosis was seen in 16 patients and graded as mild (n = 5), moderate (n = 2) or severe (n = 91, depending on the depth of involvement of the corpus spongiosum. Sonourethrography was unsatisfactory in the evaluation of membranous strictures, failing to visualize the proximal limit of the stricture.


📜 SIMILAR VOLUMES


Sonographic evaluation of the anterior l
✍ Naruhiko Nagata; Hayato Miyachi; Atsushi Nakano; Kazuhide Nanri; Hisao Kobayashi 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 256 KB

## Abstract ## Purpose We studied the sonographic appearance of the anterior liver surface using an ultrasound scanner equipped with a 7.5‐MHz annular‐array transducer to determine the accuracy of this imaging modality in monitoring the course of chronic liver diseases. ## Methods We prospective