Abstract

Purpose

This study was undertaken to assess whether changes in umbilical cord vessel morphometry are associated with an increased risk of adverse perinatal outcome among fetuses with a lean umbilical cord on sonography.

Patients and Methods

A total of 160 fetuses with a sonographically lean umbilical cord (cross‐sectional area below the 10^th^ percentile for gestational age) after 20 weeks of gestation were enrolled. The cross‐sectional areas of the umbilical cord and its vessels were measured. Outcome variables investigated were perinatal death, admission to the neonatal intensive care unit, intrauterine growth restriction, and 5‐minute Apgar score.

Results

The proportions of perinatal death (1/96 versus 6/64, p < 0.05) and admission to the neonatal intensive care unit (17/96 versus 22/64, p < 0.05) was significantly higher among fetuses with an umbilical vein area below or equal to the 10^th^ percentile for gestational age than among those with an umbilical vein area greater than the 10^th^ percentile. No differences were found in the proportions of perinatal death, neonatal intensive care unit admission, 5‐minute Apgar score < 7, and intrauterine growth restriction when fetuses with umbilical vein areas below or equal to the 10^th^, the 5^th^, and the 2.5^th^ percentiles for gestational age were compared. No difference was found in the umbilical artery area and Wharton's jelly area among the groups.

Conclusion

Among fetuses with a sonographically lean umbilical cord, a significant relationship exists between an umbilical vein area below or equal to the 10^th^ percentile and an adverse neonatal outcome. © 2004 Wiley Periodicals, Inc. J Clin Ultrasound 33:18–23, 2005


📜 SIMILAR VOLUMES


Prenatal sonographic diagnosis of short
✍ David M. Sherer; Mudar Dalloul; Olusegun Ajayi; Mila Kheyman; Margarita Sokolovs 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 126 KB

## Abstract Short umbilical cords are associated with fetal anomalies, often including those with decreased or absent fetal movement, fetal akinesia/hypokinesia sequence, and restrictive dermopathies and aneuploidy. In normal fetuses, abnormally short umbilical cords have been associated with an in

Linear disruption of umbilical cord: A r
✍ Thomson, Laura L.; Hoo, Joe J. 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 6 KB

We report on a non-malformed child with severe microcephaly and profound psychomotor delay. Review of the deliveryhirth records documented descriptions consistent with linear disruption of the umbilical cord. This rare anomaly typically leads to acute fetal distress and perinatal death. Severe micro