✦ Synopsis


Abstract

Purpose

The purpose of this study was to evaluate the ability of 4 liquid boluses to enhance pixel brightness and the ease with which the boluses could be identified during the sonographic evaluation of oral swallowing in healthy young adults.

Methods

Ten healthy adult volunteers (5 men and 5 women), ranging in age from 21 to 31 years, underwent sonographic evaluation of the oral phase of swallowing while sitting in their usual feeding position. We compared the ability of the 4 following liquids to improve sonographic visualization of swallowing with that of water: a carbonated cola beverage, 5.0 ml of Thick‐It in 120 ml of water, 2.5 ml of Thick‐It in 120 ml of water, and 7.5 ml of confectioners' sugar in 120 ml of water. Water was used as a control. In each case, 5 ml of the liquid was introduced into the subject's oral cavity using a syringe, and the subject was instructed to swallow. Digitized still images and recorded video sequences of sonographic examinations of the swallowing were analyzed. The brightness of the bolus image on selected digitized video frames was measured digitally using Image Analyst software. Pixel brightness within selected regions of interest for each of the test liquids was statistically compared with that for water. Seven clinicians rated the visualization of each test liquid and water on paired sonographic videotape sequences. These ratings and the level of agreement between them were statistically tested.

Results

Only the carbonated cola beverage demonstrated statistically greater pixel brightness than that of water on digitized video frames (p = 0.01), whereas both cola (with a moderate inter‐rater agreement, κ = 0.50) and 5.0 ml Thick‐It mixed with 120 ml of water (with a fair inter‐rater agreement, κ = 0.24) were significantly better visualized on sonographic video sequences.

Conclusions

The digital still‐frame analysis confirmed the clinicians' ratings of bolus visualization on real‐time sonography, but dynamic sonography is more important than still frames in assessing sonographic swallow media because the dynamic images more closely parallel what is seen in clinical practice. Future investigations of sonographic contrast agents for use in the examination of the oral phase of swallowing should use both static digital (still‐frame) and dynamic (real‐time) assessment methods, as well as expert reviewers. © 2002 John Wiley & Sons, Inc. J Clin Ultrasound 30:83–87, 2002; DOI 10.1002/jcu.10034


📜 SIMILAR VOLUMES


The influence of bolus volume and viscos
✍ Jeri L. Miller; Kenneth L. Watkin 📂 Article 📅 1996 🏛 Springer 🌐 English ⚖ 718 KB

The influence of bolus volume and viscosity on the distribution of anterior lingual force during the oral stage of swallowing was investigated using a new force transducer technology. The maximum force amplitudes from 5 normal adults were measured simultaneously at the mid-anterior, right, and left

Optimization of single injection liver a
✍ Puneet Sharma; Bobby Kalb; Hiroumi D. Kitajima; Khalil N. Salman; Bobbie Burrow; 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 856 KB

## Abstract ## Purpose: To measure contrast agent enhancement kinetics in the liver and to further evaluate and develop an optimized gadolinium enhanced MRI using a single injection real‐time bolus‐tracking method for reproducible imaging of the transient arterial‐phase. ## Materials and Methods:

Liver parenchymal enhancement of hepatoc
✍ Utaroh Motosugi; Tomoaki Ichikawa; Hironobu Sou; Katsuhiro Sano; Licht Tominaga; 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 218 KB

## Abstract ## Purpose: To clarify the factors that predict enhancement of the liver parenchyma in hepatocyte‐phase of gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd‐EOB‐DTPA)‐enhanced MR imaging. ## Materials and Methods: Gd‐EOB‐DTPA–enhanced hepatocyte‐phase MR images of 198 pa