## Abstract Methodology for quantitative determination of an antiβinflammatory drug, naproxen, in human serum by capillary electrophoresis (CE) is described. Ultraviolet absorbance (UV) and laserβinduced fluorescence (LIF) detection without derivatization procedures have been applied in two concent
Some factors affecting enantiomeric impurity determination by capillary electrophoresis using ultraviolet and laser-induced fluorescence detection
β Scribed by Hong Wan; Staffan Schmidt; Leon Carlsson; Lars G. Blomberg
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 180 KB
- Volume
- 20
- Category
- Article
- ISSN
- 0173-0835
No coin nor oath required. For personal study only.
β¦ Synopsis
Some factors affecting enantiomeric impurity determination by capillary electrophoresis using ultraviolet and laser-induced fluorescence detection
The key factors influencing enantiomer trace determination were investigated; these include resolution capillary diameter, limit of detection, linear range and type of detection. Chiral reagents, (+)-and (Β±)-1-(9-fluorenyl)ethyl chloroformate (FLEC), were employed as probes to demonstrate the influence of the variables. In order to find the best resolution, separation variables were optimized in both capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) modes by the application of factorial design experiments. A highly efficient chiral separation of the ()-FLEC, derivatized with nonchiral amino acids, was achieved when using gcyclodextrin as the chiral selector. The benefits of using a small diameter capillary for direct determination of both (+) and (Β±)-FLEC impurity (0.05Β±0.1% area/area) were demonstrated using UV detection and applying a sample stacking condition. A frequency-doubled argon ion laser (244 nm) was used as light source for laser-induced fluorescence (LIF) detection. Excitation light was provided by means of an optical fiber directed into the Hewlett Packard 3D capillary cartridge. The signals from UV and LIF were monitored simultaneously. The application of LIF detection greatly improved sensitivity and linear range. Further, as a consequence of the increased sensitivity, sample loading could be decreased, which led to an improvement of separation efficiency. Direct determination of 0.005% impurity could be achieved within the linear range.
π SIMILAR VOLUMES
## Determination of phycobiliproteins by capillary electrophoresis with laser-induced fluorescence detection Phycobiliproteins are derived from the photosynthetic apparatus of cyanobacteria and eukaryotic algae. They are composed of a protein backbone to which linear tetrapyrrole chromophores are