𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Solid-contact ion-selective electrode with stable internal electrode

✍ Scribed by Maria Vamvakaki; Nikolas A. Chaniotakis


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
671 KB
Volume
320
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


A new substrate for the construction of solid contact ion-selective electrodes (SC-ISEs) based on a conductive and porous carbon matrix is presented. The conductive characteristics of the substrate, its controlled porosity in combination with the use of a non-aqueous second kind internal reference element offers considerable advantages over the symmetrical configurations. The SC-ISEs presented here are very easy to construct, can be made very small in size, and can be used in high pressure environments. At the same time it is shown that the characteristics of the two electrodes constructed (K+ and NO;) exhibit at least the same performance characteristics as the best commercially available symmetric counterparts. The potentiometric response is monitored over a period of one month with excellent results with regard to drift, base line stability, response time, selectivity, and detection limit.


📜 SIMILAR VOLUMES


Solid Contact Micropipette Ion Selective
✍ Gergely Gyetvai; Sören Sundblom; Lívia Nagy; Ari Ivaska; Géza Nagy 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 385 KB

## Abstract New solid contact ammonium micropipette electrodes (ISE), well applicable in scanning electrochemical microscopy are reported. The solid contact was made of a PEDOT nanowire coated carbon fiber, lowered down close to the orifice, and dipped inside the cocktail being in the pipette tip.

Novel Thallium(III) Solid-Contact Ion-Se
✍ Sergey V. Kharitonov; Yana V. Zarembo; Viktor I. Zarembo 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 159 KB

## Abstract A solid‐contact ion‐selective electrode for thallium(III) based on its complex with new complexone __N__,__N__′‐dioctylethylenediamine‐__N__,__N__′‐disuccinic acid ([Tl(DOEDDSA)]^−^) into a polymeric membrane is described. The ion‐to‐electron transducer used as the solid contact electro

Solid-State Ion-Selective Electrode Arra
✍ Aogán Lynch; Dermot Diamond; Patrick Lemoine; Jim McLaughlin; Matt Leader 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 154 KB
Solid Contact Micropipette Ion Selective
✍ Gergely Gyetvai; Lívia Nagy; Ari Ivaska; István Hernadi; Géza Nagy 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 316 KB

## Abstract Micropipette ion selective electrodes are very small, but fragile, short‐life time sensors with very high resistance. Their high resistance is a draw back considering application in scanning electrochemical microscopy (SECM) and in life sciences. New, low resistance potassium micropipet