Sodium 3-D MRI of the human torso using a volume coil
✍ Scribed by Günter Steidle; Hansjörg Graf; Fritz Schick
- Publisher
- Elsevier Science
- Year
- 2004
- Tongue
- English
- Weight
- 527 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0730-725X
No coin nor oath required. For personal study only.
✦ Synopsis
Sodium MR imaging is considered to provide clinically important information about the human body that is not achievable by hydrogen-based approaches. However, due to the low natural abundance in biological tissues, sodium signals usually lead to low spatial resolution, low SNR, and long acquisition times compared to conventional 1H imaging, even using well-adapted surface coils. For our study, a volume coil was designed with nearly homogeneous excitation/receive characteristics and a suitable geometry fitting the human torso. A sufficient penetration throughout the entire thorax, abdomen, or pelvis is provided allowing for sodium imaging of the kidneys, the liver with gall bladder, or the myocardium. All measurements were performed on a 1.5 T whole body scanner using a spoiled 3-D gradient echo sequence. Imaging parameters TE, TR, and readout bandwidth were optimized for sensitive recording of the sodium component with slow transverse relaxation. Nonselective RF excitation pulses with a duration of 2.5 ms and rectangular shape were applied to avoid SAR problems. Narrow receiver bandwidth and excitation near the Ernst angle provided clinically practicable examinations with measuring times of less than 15 min at a spatial resolution of 8 x 8 x 8 mm3. Under these conditions, SNR of 11 for the kidneys and vertebral disks, 9 for the spinal canal, and 6 for the liver was achieved. A special 3-D spin echo sequence was used to determine T2, times which resulted to 15.3 +/- 1.1 ms for liver, 27.7 +/- 7.2 ms for kidneys, and 24.0 +/- 4.7 ms for the content of the spinal canal.
📜 SIMILAR VOLUMES
A new radiofrequency resonator for MR imaging of the human head is presented. The geometry consists of a single end-ring connected to eight legs which extend along a cylinder and are joined in pairs on a hemispherical dome. The most homogeneous normal mode of this structure is doubly degenerate and
g-Aminobutyric acid (GABA) is the major inhibitory neurotransmitter in human brain and has been implicated in several neuropsychiatric disorders. In vivo human brain GABA concentrations are near the detection limit for magnetic resonance spectroscopy (~1 mM), and because of overlap with more abundan
## Abstract ## Purpose To compare the data quality and ease of use of four endorectal‐coil probe setups for prostate MRI. ## Materials and Methods Four endorectal‐coil probe setups were compared: 1) air‐inflated probe; 2) perfluorocarbon (PFC)‐inflated probe; 3) rigid, smaller prototype coil; an
## Abstract ## Purpose To evaluate the feasibility of single breath‐hold, multiarterial MRI of the liver using the THRIVE‐CENTRA‐keyhole technique. ## Materials and Methods Twenty‐eight patients with 63 focal hepatic lesions underwent liver MR examinations that included the three‐dimensional THR