✦ Synopsis


Because of the continuing trend toward earlier repair of hypospadias, improved visualization of tissues is important. We have reviewed 33 consecutive hypospadias repairs performed using the operating microscope. Complications included three strictures (9.1%) and five fistulae (15.1Β°/o). The microscope proved most useful in resident teaching, allowing both surgeon and assistant to visualize optimally the tissues.


πŸ“œ SIMILAR VOLUMES


Single-stage repair of subglottic stenos
✍ Kumar G. Prasad; Mark A. Varvares; Michael J. Odell πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 178 KB

## Abstract ## Background. We present a case report of a patient with history of subglottic carcinoma who underwent chemoradiation and subsequently developed subglottic stenosis (SGS). ## Methods and Results. She was treated with an anterior cricoid split maintained by septal cartilage wrapped i

Optimum specimen positioning in the elec
✍ Turner, J. N. ;Rieder, C. L. ;Collins, D. N. ;Chang, B. B. πŸ“‚ Article πŸ“… 1989 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 852 KB

Optimal imaging of complex structures requires proper alignment relative to the optic axis of the electron microscope. This is especially important for high-voltage and intermediatevoltage microscopes, which form an in-focus image throughout the entire thickness of the object. As a result, structure

Determination of particle number and bri
✍ Rooshin B. Dalal; Michelle A. Digman; Alan F. Horwitz; Valeria Vetri; Enrico Gra πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 810 KB

## Abstract We describe a method to obtain the brightness and number of molecules at each pixel of an image stack obtained with a laser scanning microscope. The method is based on intensity fluctuations due to the diffusion of molecules in a pixel. For a detector operating in the analog mode, the v

Experimental study of the use of additiv
✍ W. Rivera; J. Cerezo πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 167 KB πŸ‘ 2 views