Simultaneous measurement of arterial input function and tumor pharmacokinetics in mice by dynamic contrast enhanced imaging: Effects of transcytolemmal water exchange

✍ Scribed by Rong Zhou; Stephen Pickup; Thomas E. Yankeelov; Charles S. Springer Jr.; Jerry D. Glickson


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
367 KB
Volume
52
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A noninvasive technique for simultaneous measurement of the arterial input function (AIF) for gadodiamide (Omniscan) and its uptake in tumor was demonstrated in mice. Implantation of a tumor at a suitable location enabled its visualization in a cardiac short axis image. Sets of gated, low‐resolution saturation recovery images were acquired from each of five tumor‐bearing mice following intravenous administration of a bolus of contrast agent (CA). The AIF was extracted from the signal intensity changes in left ventricular blood using literature values of the CA relaxivity and a precontrast T~1~ map. The time‐dependent ^1^H~2~O relaxation rate constant (R~1~ = 1/T~1~) in the tumor was modeled using the BOLus Enhanced Relaxation Overview (BOLERO) method in two modes regarding the equilibrium transcytolemmal water exchange system: 1) constraining it exclusively to the fast exchange limit (FXL) (the conventional assumption), and 2) allowing its transient departure from FXL and access to the fast exchange regime (FXR), thus designated FXL/FXR. The FXL/FXR analysis yielded better fittings than the FXL‐constrained analysis for data from the tumor rims, whereas the results based on the two modes were indistinguishable for data from the tumor cores. For the tumor rims, the values of K^trans^ (the rate constant for CA transfer from the vasculature to the interstitium) and v~e~ (volume fraction of the tissue extracellular and extravascular space) returned from FXL/FXR analysis are consistently greater than those from the FXL‐constrained analysis by a factor of 1.5 or more corresponding to a CA dose of 0.05 mmole/kg. Magn Reson Med 52:248–257, 2004. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Improving the pharmacokinetic parameter
✍ Xiangyu Yang; Jiachao Liang; Johannes T. Heverhagen; Guang Jia; Petra Schmalbroc 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 715 KB

## Abstract One of the most powerful features of the dynamic contrast‐enhanced (DCE) MRI technique is its capability to quantitatively measure the physiological or pathophysiological environments assessed by the passage of contrast agent by means of model‐based pharmacokinetic analysis. The widely

The effect of blood inflow and B1-field
✍ Caleb Roberts; Ross Little; Yvonne Watson; Sha Zhao; David L. Buckley; Geoff J. 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 812 KB

## Abstract A major potential confound in axial 3D dynamic contrast‐enhanced magnetic resonance imaging studies is the blood inflow effect; therefore, the choice of slice location for arterial input function measurement within the imaging volume must be considered carefully. The objective of this s