Simultaneous in vivo spectral editing and water suppression
โ Scribed by M. Mescher; H. Merkle; J. Kirsch; M. Garwood; R. Gruetter
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 163 KB
- Volume
- 11
- Category
- Article
- ISSN
- 0952-3480
No coin nor oath required. For personal study only.
โฆ Synopsis
Water suppression is typically performed in vivo by exciting the longitudinal magnetization in combination with dephasing, or by using frequency-selective coherence generation. MEGA, a frequency-selective refocusing technique, can be placed into any pulse sequence element designed to generate a Hahn spin-echo or stimulated echo, to dephase transverse water coherences with minimal spectral distortions. Water suppression performance was verified in vivo using stimulated echo acquisition mode (STEAM) localization, which provided water suppression comparable with that achieved with four selective pulses in 3,1-DRYSTEAM. The advantage of the proposed method was exploited for editing J-coupled resonances. Using a double-banded pulse that selectively inverts a J-coupling partner and simultaneously suppresses water, efficient metabolite editing was achieved in the point resolved spectroscopy (PRESS) and STEAM sequences in which MEGA was incorporated. To illustrate the efficiency of the method, the detection of g-aminobutyric acid (GABA) was demonstrated, with minimal contributions from macromolecules and overlying singlet peaks at 4 T. The estimated occipital GABA concentration was consistent with previous reports, suggesting that editing for GABA is efficient when based on MEGA at high field strengths.
๐ SIMILAR VOLUMES
## Abstract A method to achieve simultaneous water and lipid suppression is described. The key feature of the new dual suppression technique is the use of the wellโknown hyperbolic secant (HS) waveform as a 90ยฐ saturation pulse. Two HS pulses with opposite frequency offsets are employed either sequ
## Abstract It is shown that double inversion recovery used for water suppression can be made much less sensitive to pulse imperfections and to the variations in the relaxation times than a single inversion recovery. This insensitivity results in up to 10โfold improvement in the water suppression _
Conventional double quantum (DQ) editing techniques recover resonances of one metabolite at a time and are thus inefficient for monitoring metabolic changes involving several metabolites. A DQ coherence transfer double editing sequence using a dual-band DQ coherence read pulse is described here. The
## Abstract A novel selective homonuclear HartmannโHahn transfer method for in vivo spectral editing is proposed and applied to measurements of ฮณโaminobutyric acid (GABA) in the human brain at 3 T. The proposed method utilizes a new concept for in vivo spectral editing, the spectral selectivity of