Simulators for medical training: application to vascular ultrasound imaging
โ Scribed by Troccaz, Jocelyne ;Henry, Delphine ;Laieb, Noureddine ;Champleboux, Guillaume ;Bosson, Jean-Luc ;Pichot, Olivier
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 550 KB
- Volume
- 11
- Category
- Article
- ISSN
- 1049-8907
No coin nor oath required. For personal study only.
โฆ Synopsis
Whilst computers are more and more used in the medical and surgical domains, medical education is still very conservative. However, new information technology could bring a lot to this area. In particular, simulators are of paramount interest: they would allow one both to experiment with surgical or imaging techniques for a wide range of pathologies without the need for patients and to quantitatively evaluate the trainees' performances. Ultrasound imaging is a typical area where virtual reality may change educational uses. This paper describes an ultrasound imaging simulator dedicated to the training of physicians for the detection of deep venous thromboses of the lower limbs. Like this one, a lot of other pathologies of soft tissue are diagnosed using ultrasound imaging. Because this examination is difยฎcult and operator-dependent, developing a simulator is very useful to give common databases of pathological samples on which physicians can both experiment with image acquisition and evaluate their understanding of clinical cases. Real-time simulation is mandatory. An ultrasound imaging simulator has been developed and is being tested. This paper presents the hardware and software components of the simulator and describes the status of this project.
๐ SIMILAR VOLUMES
The support vector domain description is a one-class classification method that estimates the distributional support of a data set. A flexible closed boundary function is used to separate trustworthy data on the inside from outliers on the outside. A single regularization parameter determines the sh
## Abstract A computer simulation program capable of demonstrating various artifacts, such as image distortion caused by metallic implants in MR imaging, is presented. The structure of the program allows for the implementation of various imaging situations as long as spins only experience weak inte
Spatial resolution is a key parameter of all kind of images. This is of particular importance in fields as, for example, medicine or remote sensing. The nominal resolution of a positron emission tomography (PET) or nuclear magnetic resonance (NMR) scanners are directly related to the size, number, a
## Abstract __T__~1~โweighted contrast is conventionally obtained using multislice twoโdimensional (2D) spinโecho (SE) imaging. Achieving isotropic, high spatial resolution is problematic with conventional methods due to a long acquisition time, imperfect slice profiles, or highโenergy deposition.