𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Signal-to-Noise Ratio Comparison of Encoding Methods for Hyperpolarized Noble Gas MRI

✍ Scribed by Lei Zhao; Arvind K. Venkatesh; Mitchell S. Albert; Lawrence P. Panych


Publisher
Elsevier Science
Year
2001
Tongue
English
Weight
138 KB
Volume
148
Category
Article
ISSN
1090-7807

No coin nor oath required. For personal study only.

✦ Synopsis


Some non-Fourier encoding methods such as wavelet and direct encoding use spatially localized bases. The spatial localization feature of these methods enables optimized encoding for improved spatial and temporal resolution during dynamically adaptive MR imaging. These spatially localized bases, however, have inherently reduced image signal-to-noise ratio compared with Fourier or Hadamad encoding for proton imaging. Hyperpolarized noble gases, on the other hand, have quite different MR properties compared to proton, primarily the nonrenewability of the signal. It could be expected, therefore, that the characteristics of image SNR with respect to encoding method will also be very different from hyperpolarized noble gas MRI compared to proton MRI. In this article, hyperpolarized noble gas image SNRs of different encoding methods are compared theoretically using a matrix description of the encoding process. It is shown that image SNR for hyperpolarized noble gas imaging is maximized for any orthonormal encoding method. Methods are then proposed for designing RF pulses to achieve normalized encoding profiles using Fourier, Hadamard, wavelet, and direct encoding methods for hyperpolarized noble gases. Theoretical results are confirmed with hyperpolarized noble gas MRI experiments.


πŸ“œ SIMILAR VOLUMES


Comparison between signal-to-noise ratio
✍ Alberto Fenzi; Mirko Bortolazzi; Pasquina Marzola πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 217 KB

## Abstract ## Purpose To compare different MRI‐derived parameters, i.e., liver signal‐to‐noise ratio (LSNR), liver‐to‐muscle ratio (LMR) and liver transversal relaxation rate (R2), in terms of their correlation with the ex vivo determined iron content in an experimental model of liver iron overlo

Computationally rapid method of estimati
✍ Curtis N. Wiens; Shawn J. Kisch; Jacob D. Willig-Onwuachi; Charles A. McKenzie πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 639 KB

## Abstract Measuring signal‐to‐noise ratio (SNR) for parallel MRI reconstructions is difficult due to spatially dependent noise amplification. Existing approaches for measuring parallel MRI SNR are limited because they are not applicable to all reconstructions, require significant computation time

Functional MRI using multiple receiver c
✍ Volker Hesselmann; Ralf Girnus; Christoph Wedekind; Stefan Hunsche; Juergen Bunk πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 556 KB

## Purpose: To compare the performance of single shot echo planar imaging (ssepi) with three-dimensional-multishot echo-planar imaging (epi) based on principles-of-echo-shifting-with-a-train-of-observations (presto) in combination with a standard quadrature head coil and, as an alternative, a multi