𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Shared k-space echo planar imaging with keyhole

✍ Scribed by M. Zaitsev; K. Zilles; N.J. Shah


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
422 KB
Volume
45
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Time-dependent phenomena are of great interest, and researchers have sought to shed light on these processes with MRI, particularly in vivo. In this work, a new hybrid technique based on EPI and using the concept of keyhole imaging is presented. By sharing peripheral k-space data between images and acquiring the keyhole more frequently, it is shown that the spatial resolution of the reconstructed images can be maintained. The method affords a higher temporal resolution and is more robust against susceptibility and chemical-shift artifacts than single-shot EPI. The method, termed shared k-space echo planar imaging with keyhole (shared EPIK), has been implemented on a standard clinical scanner. Technical details, simulation results, phantom images, in vivo images, and fMRI results are presented. These results indicate that the new method is robust and may be used for dynamic MRI applications.


📜 SIMILAR VOLUMES


Image reconstruction for echo planar ima
✍ H. Bruder; H. Fischer; H.-E. Reinfelder; F. Schmitt 📂 Article 📅 1992 🏛 John Wiley and Sons 🌐 English ⚖ 667 KB

## Abstract Echo planar imaging is characterized by scanning the 2D __k__‐space after a single excitation. Different sampling patterns have been proposed. A technically feasible method uses a sinusoidal readout gradient resulting in measured data that does not sample __k__‐space in an equidistant m

Cardiac imaging: Comparison of two-shot
✍ Daniel A. Leung; Jörg F. Debatin; Simon Wildermuth; Graeme C. McKinnon; Gustav K 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 665 KB

## Abstract We compared the cardiac image quality of multishot echo‐planar imaging (EPI), segmented K‐space, and conventional cine acquisitions. Three techniques were used to obtain gated multiphase acquisitions of an axial section traversing both ventricles in 10 volunteers: two‐shot EPI acquired

Partial k-space reconstruction in single
✍ Pippa Storey; Fred J. Frigo; R. Scott Hinks; Bryan J. Mock; Bruce D. Collick; Ni 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 967 KB

## Abstract Partial __k__‐space sampling is frequently used in single‐shot diffusion‐weighted echo‐planar imaging (DW‐EPI) to reduce the TE and thereby improve the SNR. However, it increases the sensitivity of the technique to bulk rotational motion, which introduces a phase gradient across the tis

Normal myocardial perfwsion assessed wit
✍ Jürg Schwitter; Jorg F. Debatin; Gustav K. von Schulthess; Graeme C. McKinnon 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 995 KB

## Abstract A new magnetic resonance imaging strategy is presented for accessing myocardial perfusion. Most previous work has relied on using __T__~1~‐weighted fast gradient‐echo imaging to monitor dynamically the signal changes during the passage of a contrast media bolus. However, the gradient‐ec

Echo planar imaging at 4 tesla with mini
✍ Dardo G. Tomasi; Thomas Ernst 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 160 KB

## Abstract ## Purpose To minimize the acoustic sound pressure levels of single‐shot echo planar imaging (EPI) acquisitions on high magnetic field MRI scanners. ## Materials and Methods The resonance frequencies of gradient coil vibrations, which depend on the coil length and the elastic propert