Severe orbital floor fractures: repair with a titanium implant

โœ Scribed by A.K. Lo; I. T. Jackson; J. H. Ross; C. B. Dickson


Book ID
104658467
Publisher
Springer
Year
1992
Tongue
English
Weight
675 KB
Volume
15
Category
Article
ISSN
1435-0130

No coin nor oath required. For personal study only.

โœฆ Synopsis


Fractures of the orbital floor which require exploration are usually treated with an alloplastic floor implant or an autogenous bone graft. When large portions of the orbital floor, together with the lower parts of lateral and medial walls, are destroyed there may be no possibility of providing a conventional orbital floor reconstruction. In this situation, a titanium orbital floor implant may well be required to support the globe. 4 cases of traumatic orbital floor blow-out fractures are described. Clinically, all patients had diplopia, enophthalmos and radiological evidence of extensive loss of the orbital floor. A titanium orbital floor implant was molded and secured to the infraorbital rim with miniscrews to reconstruct the orbital floor and to reconstitute Requests for reprints.