Separation of enzymes from microorganism crude extracts by free-flow zone electrophoresis
✍ Scribed by Sunil Nath; Horst Schütte; Helmut Hustedt; Wolf-Dieter Deckwer; Gerhard Weber
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 769 KB
- Volume
- 51
- Category
- Article
- ISSN
- 0006-3592
No coin nor oath required. For personal study only.
✦ Synopsis
Continuous, single-step, state-of-the-art preparative separations of enzymes from microorganism crude extracts by free-flow zone electrophoresis are presented. In the first example, the enzymes formate dehydrogenase, formaldehyde dehydrogenase, and methanol oxidase were continuously separated from Candida boidiniicrude extract. Yields of 85% to 95% and purification factors between 3 and 7 were obtained along with a simultaneous separation ofthe finer cell debrisfrom the enzymes. Using multiple injections of sample, a throughput of 46.2 mg protein/h was recorded. In the second example, a fivefold purification of P-galactosidase from Escherichia coli was achieved along with complete, simultaneous cell debris separation from the enzyme. The yield of the enzyme was greater than 90%. The preparative free-flow zone electrophoresis experiments were run continuously for a period of 12 h and the separations were found to be stable; i.e., the enzymes and the cell debris eluted at their respective fraction numbers during the entire period. In both examples, choice of the type of buffer played a critical role and had to be investigated and optimized experimentally. Scale-up aspects of the separations are also discussed. Recently, by comparison of free-flow zone electrophoresis with ion-exchange chromatography, we have presented evidence that free-flow electrophoresis separations are governed by net surface charge 6. Nath et at., Biotechnol. Bioeng. 1993, 42: 829-835). Here, we offer further confirmation of this evidence by comparison of preparative free-flow zone electrophoresis experiments at various pHs on a mixture of two model proteins with analytical electrophoretic titration curves of the proteins. We are thus in a position to predict separations in free-flow zone electrophoresis. 0 1996 John Wiley & Sons, Inc.
Key words:
📜 SIMILAR VOLUMES
## Abstract Suspensions of rat kidney cells obtained by disaggregation of the kidney with 0.25% trypsin were separated by electrophoresis. Previously, we found a correlation between cells with histochemically demonstrable alkaline phosphatase (HDAP) and cells with brush borders which established th