𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Separation and concentration of baicalin from Scutellaria Baicalensis Georgi extract by aqueous two-phase flotation

✍ Scribed by Bi, Peng-yu; Chang, Lin; Mu, Ying-lin; Liu, Jian-you; Wu, Yu; Geng, Xue; Wei, Yun


Book ID
120538432
Publisher
Elsevier Science
Year
2013
Tongue
English
Weight
422 KB
Volume
116
Category
Article
ISSN
1383-5866

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Extraction of cephalosporin C from whole
✍ Wu-Yung Yang; Chun-Der Lin; I-Ming Chu; Chau-Jen Lee πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 590 KB

Cephalosporin C was extracted from diluted or whole broth by PEG/salt aqueous two-phase systems. Parameters such as PEG molecular weight, salt type, pH, and salt concentration were investigated for finding a suitable extraction system. In PEG 600/ammoninum sulfate or phosphate systems, K, (partition

Separation of genomic DNA, RNA, and open
✍ Andreas Frerix; Petra Geilenkirchen; Markus MΓΌller; Maria-Regina Kula; JΓΌrgen Hu πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 377 KB πŸ‘ 2 views

## Abstract In the current study we developed a process for the capture of pDNA exploiting the ability of aqueous two‐phase systems to differentiate between different forms of DNA. In these systems scpDNA exhibits a near quantitative partitioning in the salt‐rich bottom phase. The successive recove

Saliva and serum samples were collected
Saliva and serum samples were collected from eight healthy volunteers every two hours during a 26-hour period. Melatonin concentrations were measured by radioimmunoassay after chloroform extraction using radioiodinated melatonin as a tracer. Five of the subjects had high serum melatonin levels at night (peak levels higher than 75 pg/ml); in three subjects the highest serum melatonin concentration was 20-40 pg/ml. All subjects had low levels (P <0.001, was obtained for all detectable value pairs (n= 73). The regression and correlation coefficients were almost equal for the peak values of melatonin and during the rising and descending phases of the secretion patterns. However, no significant correlation was found between low daytime salivary and serum concentrations when calculated separately. In the five high-secretors the melatonin levels in saliva reflected reliably the changes in serum, but in the three low-secretors the correlation between salivary and serum melatonin was not significant. The proportion of melatonin found in saliva decreased with increasing serum melatonin levels. Circadian rhythm parameters were estimated by single cosinor analysis. The acrophases did not differ significantly within a subject in the concomitant measurements of serum and salivary melatonin. The measurements of salivary melatonin levels seem valid for studies on melatonin rhythms, but the melatonin concentrations measured in saliva do not always consistently reflect the absolute concentrations in blood.
✍ Maija-Liisa Laakso; Tarja Porkka-Heiskanen; Aino Alila; Dag Stenberg; Gunnar Joh πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 622 KB