Semiautomatic off-resonance correction in spiral imaging
✍ Scribed by Weitian Chen; Craig H. Meyer
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 419 KB
- Volume
- 59
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Spiral scanning is a promising MRI method, but one limitation is that off‐resonance effects can cause image blurring. Most current off‐resonance correction methods for spiral imaging require an accurate field map, which is difficult to obtain in many applications. Automatic methods can perform off‐resonance correction without acquiring a field map. However, these methods are computationally inefficient and relatively prone to estimation error. This study describes a new semiautomatic off‐resonance correction method that combines an automatic method with a low resolution field map acquisition for off‐resonance correction in spiral scanning. Experiments demonstrate that this method is more robust than conventional automatic off‐resonance correction and can provide more accurate off‐resonance correction than conventional field map based methods. The proposed method is also computationally efficient and has been implemented for online reconstruction. Magn Reson Med 59:1212–1219, 2008. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Field inhomogeneity and susceptibility variations, coupled with a long readout, can result in image blurring in spiral imaging. Many correction methods based on a priori off‐resonance information, such as an acquired field map, have been proposed in the literature. Automatic off‐resonan
To integrate water-fat-resolved spiral gradientecho imaging with off-resonance correction into a clinical MR scanner and to evaluate its basic feasibility and performance. Materials and Methods: Three-point chemical shift imaging was implemented with forward and strongly T 2 \*weighted reverse spir
## Abstract One primary disadvantage of spiral imaging is blurring artifact due to off‐resonance effects. The conventional frequency segmented off‐resonance correction method that is performed over the entire image is computationally intense due to the large number of fast Fourier transforms (FFTs)
## Abstract We present, here, a simple method for measurement and correction of off‐resonance related geometric distortion in echo‐planar imaging (EP1). This method uses high signal‐to‐noise ratio (SNR) EPI‐based field maps, rapidly acquired using a series of gradient recalled images collected acro