𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Self-gated cardiac cine MRI

✍ Scribed by Andrew C. Larson; Richard D. White; Gerhard Laub; Elliot R. McVeigh; Debiao Li; Orlando P. Simonetti


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
250 KB
Volume
51
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The need for ECG gating presents many difficulties in cardiac magnetic resonance imaging (CMRI). Real‐time imaging techniques eliminate the need for ECG gating in cine CMRI, but they cannot offer the spatial and temporal resolution provided by segmented acquisition techniques. Previous MR signal‐based techniques have demonstrated an ability to provide cardiac gating information; however, these techniques result in decreased imaging efficiency. The purpose of this work was to develop a new “self‐gated” (SG) acquisition technique that eliminates these efficiency deficits by extracting the motion synchronization signal directly from the same MR signals used for image reconstruction. Three separate strategies are proposed for deriving the SG signal from data acquired using radial k‐space sampling: echo peak magnitude, kymogram, and 2D correlation. The SG techniques were performed on seven normal volunteers. A comparison of the results showed that they provided cine image series with no significant differences in image quality compared to that obtained with conventional ECG gating techniques. SG techniques represent an important practical advance in clinical MRI because they enable the acquisition of high temporal and spatial resolution cardiac cine images without the need for ECG gating and with no loss in imaging efficiency. Magn Reson Med 51:93–102, 2004. © 2003 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Wireless self-gated multiple-mouse cardi
✍ Emilio Esparza-Coss; Marc S. Ramirez; James A. Bankson 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 638 KB

## Abstract Despite the excellent image‐contrast capability of MRI and the ability to synchronize MRI with the murine cardiac cycle, this technique is underused for assessing mouse models of cardiovascular disease because of its perceived cost and complexity. This perception stems, in part, from co

Comparison of self-gated cine MRI retros
✍ Grace M. Nijm; Alan V. Sahakian; Steven Swiryn; James C. Carr; John J. Sheehan; 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 161 KB

## Abstract ## Purpose To determine whether improved self‐gating (SG) algorithms can provide superior synchronization accuracy for retrospectively gated cine MRI. ## Materials and Methods First difference, template matching, and polynomial fitting algorithms were implemented to improve the synch

Automated rectilinear self-gated cardiac
✍ Mark E. Crowe; Andrew C. Larson; Qiang Zhang; James Carr; Richard D. White; Debi 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 453 KB

## Abstract ECG‐based gating in cardiac MR imaging requires additional patient preparation time, is susceptible to RF and magnetic interference, and is ineffective in a significant percentage of patients. “Wireless” or “self‐gating” techniques have been described using either interleaved central __

Cardiac and respiratory double self-gate
✍ Bassem Hiba; Nathalie Richard; Marc Janier; Pierre Croisille 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 992 KB

## Abstract ECG‐gated cardiac MRI in the mouse is hindered by many technical difficulties in ECG signal recording inside static and variable high magnetic scanner fields. The present study proposes an alternative robust method of acquiring auto‐gated cardiac and respiratory cine images in mouse hea

Whole-heart cine MRI using real-time res
✍ Sergio Uribe; Vivek Muthurangu; Redha Boubertakh; Tobias Schaeffter; Reza Razavi 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 486 KB

## Abstract Two‐dimensional (2D) breath‐hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three‐dimensional (3D) cardiac MR can overcome some of thes

Preliminary investigation of respiratory
✍ Andrew C. Larson; Peter Kellman; Andrew Arai; Glenn A. Hirsch; Elliot McVeigh; D 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 365 KB

## Abstract Segmented cine MRI generally requires breath‐holding, which can be problematic for many patients. Navigator echo techniques, particularly successful for free‐breathing coronary MRA, are incompatible with the acquisition strategies and SSFP pulse sequences commonly used for cine MRI. The