Self-Diffusion Imaging by Spin Echo in Earth's Magnetic Field

✍ Scribed by Aleš Mohorič; Janez Stepišnik; Miha Kos; Gorazd Planinšič


Publisher
Elsevier Science
Year
1999
Tongue
English
Weight
116 KB
Volume
136
Category
Article
ISSN
1090-7807

No coin nor oath required. For personal study only.

✦ Synopsis


The NMR of the Earth's magnetic field is used for diffusionweighted imaging of phantoms. Due to a weak Larmor field, care needs to be taken regarding the use of the usual high field assumption in calculating the effect of the applied inhomogeneous magnetic field. The usual definition of the magnetic field gradient must be replaced by a generalized formula valid when the strength of a nonuniform magnetic field and a Larmor field are comparable (J. Stepis ˇnik, Z. Phys. Chem. 190, 51-62 (1995)). It turns out that the expression for spin echo attenuation is identical to the well-known Torrey formula only when the applied nonuniform field has a proper symmetry. This kind of problem may occur in a strong Larmor field as well as when the slow diffusion rate of particles needs an extremely strong gradient to be applied. The measurements of the geomagnetic field NMR demonstrate the usefulness of the method for diffusion and flowweighted imaging.


📜 SIMILAR VOLUMES


NMR imaging in the earth's magnetic fiel
✍ J. Stepišnik; V. Eržen; M. Kos 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 344 KB

## Abstract The most important and very expensive part of a magnetic resonance imaging set‐up is the magnet, which is capable of generating a constant and highly homogeneous magnetic field. Here a new MR imaging technique without the magnet is introduced. This technique uses the earth's magnetic fi

Diffusion Measurements with the Aid of N
✍ Attila Scharfenecker; Ioan Ardelean; Rainer Kimmich 📂 Article 📅 2001 🏛 Elsevier Science 🌐 English ⚖ 79 KB

Nutation echoes are generated by radiofrequency (RF) pulses with an inhomogeneous amplitude, B 1 ‫؍‬ B 1 (r), in inhomogeneous magnetic fields, B 0 ‫؍‬ B 0 (r). The two gradients of strengths G 1 and G 0 , respectively, must be aligned in parallel for a maximum echo signal. After two RF pulses, two

Environmental optimization and shielding
✍ B. Favre; J. P. Bonhe; H. Mehier; J. O. Peyrin 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 335 KB

For many years, a number of laboratories have been working on the applications of very low field NMR. In 1985, our laboratory presented the first NMR images using the earth's magnetic field. However, the use of this technique was limited by the weakness of the signal and the disturbing effects of th