Trace enrichment for the GC analysis of a series of chlorinated pesticides and polychlorinated biphenyls (PCBs) in aqueous samples has been achieved through a simple on-line technique involving sorption on an LC micro-precolumn followed by direct elution into a gas chromatograph with hexane. A 5-m r
Selective and sensitive detection of organic contaminants in water samples by on-line trace enrichment-gas chromatography-mass spectrometry
✍ Scribed by Bulterman, Albert-J. ;Vreuls, Jolan J. ;Ghijsen, Rudy T. ;Brinkman, Udo A. Th.
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 768 KB
- Volume
- 16
- Category
- Article
- ISSN
- 0935-6304
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Liquid chromatographic (LC) type trace enrichment is coupled online with capillary gas chromatography (GC) with mass spectrometric (MS) detection for the analysis of aqueous samples. A volume of 1–10 ml of an aqueous sample is preconcentrated on a trace‐enrichment column packed with a polymeric stationary phase. After cleanup with HPLC‐grade water the precolumn is dried with nitrogen and subsequently desorbed with ethyl acetate. A fraction of 60 μl is introduced on‐line into a diphenyltetramethyldisilazane‐deactivated retention gap under partially concurrent solvent evaporation conditions and using an early solvent vapor exit. The analytes are separated and detected by means of GC–MS. The potential of the LC–GC–MS system for monitoring organic pollutants in river and drinking water is studied. Target analysis is carried out with atrazine and simazine as model compounds; the detection limits achieved under full‐scan and multiple ion detection conditions are 30 pg and 5 pg, respectively. Identification of unknown compounds (non‐target analysis), is demonstrated using a river water sample spiked with 168 pollutants varying in polarity and volatility.
📜 SIMILAR VOLUMES
An on-line sample pretreatment method was developed to preconcentrate trace metal ions from water samples. complexes of metal ions with butane-2,3-dione bis(N-pyridinoacetyt hydrazone) were retained on a column packed with Amberlite XAD-4 resin at pH 8-9. The metal complexes were removed from the co
## Abstract Two gas chromatographic methods, GC‐FID (flame ionization detection) and GC‐ELCD (electrolytic conductivity detector) are compared in tlie analysis of volatile organic sulfur compounds (VOSCs) in water samples with a membrane inlet mass spectrometry (MIMS) technique. Carbon disulfide, e
## Abstract This paper describes the extraction of 49 organophosphorus pesti‐cides (OPPs) from water samples using solid‐phase microextraction (SPME). Three fibers, including a 15‐μm XAD‐coated fiber, a 85‐μm polyacrylate‐coated fiber, and a 30‐μm polydimethylsilox‐ane‐coated fiber (PDMS), were eva