๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Seismic vibration control of short period structures using the liquid column damper

โœ Scribed by Aparna Ghosh; Biswajit Basu


Book ID
104017815
Publisher
Elsevier Science
Year
2004
Tongue
English
Weight
331 KB
Volume
26
Category
Article
ISSN
0141-0296

No coin nor oath required. For personal study only.

โœฆ Synopsis


The possibility of the application of the liquid column damper (LCD) for the seismic vibration control of short period structures has been explored. A viable model of the damper system, in which the LCD is connected by a spring to the structure, has been examined. The structure has been modeled as a linear, viscously damped single-degree-of-freedom (SDOF) system. A stochastic equivalent linearization technique has been used to linearize the nonlinear orifice damping in the LCD. A transfer function formulation for the proposed structure-LCD system has been presented. Details concerning the selection of design parameters of the damper have been supplied. Numerical studies have been carried out to demonstrate the effectiveness of the proposed system Further, the additional damping in terms of equivalent viscous damping introduced by this damper into the primary structure has been studied.


๐Ÿ“œ SIMILAR VOLUMES


Multiple-tuned liquid column dampers for
โœ K. M. Shum; Y. L. Xu ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 466 KB ๐Ÿ‘ 1 views

## Abstract This paper presents an experimental investigation on the performance of multipleโ€tuned liquid column dampers (MTLCD) for reducing torsional vibration of structures in comparison with singleโ€tuned liquid column dampers (STLCD). A large structure model simulating its torsional vibration a

Kalman filter approach for the control o
โœ Loh, Chin-Hsiung ;Lin, Pay-Yang ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 371 KB ๐Ÿ‘ 1 views

In this paper, two issues in structural control are discussed. First, the prediction-type Kalman ยฎlter approach is used to estimate the full-state variables of a building's seismic response from a limited number of measurements and the full-state feedback control strategy can be applied. The result