Segmentation of cardiac cine MR images of left and right ventricles: Interactive semiautomated methods and manual contouring by two readers with different education and experience

✍ Scribed by Francesco Sardanelli; Matteo Quarenghi; Giovanni Di Leo; Leonardo Boccaccini; Angelo Schiavi


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
382 KB
Volume
27
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To test interactive semiautomated methods (ISAM) vs. manual contouring (MC) in segmenting cardiac cine MR images.

Materials and Methods

Short‐axis images of 10 consecutive patients (1.5–81.5 years of age) were evaluated by a trained radiologist (R1) and a low‐trained engineer (R2). Each of them performed four independent reading sessions: two using ISAM and two using MC. Left ventricle (LV) myocardial mass (LVMM), LV ejection fraction (LVEF), and right ventricle (RV) ejection fraction (RVEF) were obtained. Bland‐Altman analysis and Wilcoxon test were used.

Results

The bias ± 2 standard deviations (SD) of ISAM vs. MC for LVMM (g) was –5.7 ± 13.4 (R1) and –5.5 ± 26.3 (R2); for LVEF (%) it was –1.4 ± 13.0 and –2.9 ± and 6.8; for RVEF (%) it was 2.6 ± 17.0 and 1.0 ± 16.7. Considering both readers/methods, intraobserver bias ± 2 SD ranged from 0.3 ± 25.3 to –6.8 ± 23.0, from 0.2 ± 8.0 to –4.4 ± 15.8, and from –0.0 ± 26.4 to –4.6 ± 27.8, respectively. Interobserver bias ± 2 SD was –25.9 ± 46.0 (ISAM) and 26.1 ± 36.4 (MC), –1.4 ± 8.6 (ISAM) and 0.1 ± 17.9 (MC), and 0.7 ± 23.3 and 2.3 ± 29.8, respectively. Larger SDs were systematically found for RVEF vs. LVEF. Segmentation times: five minutes for LV with ISAM (both readers); for LV with MC, six (R1) vs. nine minutes (R2) (P < 0.001); five to six minutes for RV (both methods /readers). R2 significantly reduced LV segmentation times from nine (MC) to five minutes (ISAM) (P < 0.001).

Conclusion

A highly reproducible LV segmentation was performed in a short time by R1. The advantage of ISAM vs. MC for LV segmentation was a time saving only for R2. For RVEF, a lower reproducibility was observed for both methods and readers. J. Magn. Reson. Imaging 2008. © 2008 Wiley‐Liss, Inc.