๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Sedation, anesthesia, and physiologic monitoring during MR imaging: Evaluation of procedures and equipment

โœ Scribed by Barbara A. Holshouser; David B. Hinshaw Jr.; Frank G. Shellock


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
729 KB
Volume
3
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

The authors developed safe standard sedation and general anesthesia procedures for adults and children, including adequate physiologic monitoring, during magnetic resonance (MR) imaging. Sixโ€year results are reported from one institution; 75% of the 600 patients per year who require sedation or anesthesia are children who require sedation only. Testing was done to determine MR compatibility of various types of equipment essential for monitoring and supporting sedated or anesthetized patients in 1.0โ€and 1.5โ€T MR imagers. Use of sedation procedures that include oral chloral hydrate after sleep deprivation resulted in a failure rate of 3.8% in sedating outpatient children. Every physiologic parameter that can be monitored under normal circumstances in the critical care unit or operating room can be monitored during MR imaging. Our experience indicates that with careful consideration of the unique MR environment and with rigorous testing of monitoring equipment, MR imaging can be performed safely in sedated or anesthetized patients.


๐Ÿ“œ SIMILAR VOLUMES


MR imaging during endovascular procedure
โœ Alastair J. Martin; Bryant Baek; Gabriel Acevedo-Bolton; Randall T. Higashida; J ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 629 KB

## Abstract MRI in catheterized patients is considered unsafe due to the potential for focal heating. This concern arises from the continuous metallic braid that is incorporated into catheters to provide their desired physical properties. The potential for catheter heating during MR scanning was as

Temperature monitoring during MR imaging
โœ Katherine H. Taber; L. Anne Hayman ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 238 KB

## Abstract Temperature readings from standard wire lead thermistor probes and a fluoroptic temperature probe were compared before, during, and after exposure to a spinโ€echo imaging sequence at 2.35 T. All the probes were placed in salineโ€filled vials (1โ€mL capacity) surrounded by dense foam rubber

Quantitative mr imaging data in the eval
โœ Andrea Giovagnoni; Enrico Paci; Filippo Terilli; Riccardo Cellerino; Andrea Piga ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 553 KB

## Abstract To identify changes induced by chemotherapy in hepatic metastases, 34 patients with metastases underwent magnetic resonance (MR) imaging before the start of systemic chemotherapy and monthly thereafter. The number, size, and morphologic patterns of the lesions and changes in quantitativ

Physiological changes of the human uteri
โœ Aki Kido; Takashi Koyama; Masako Kataoka; Akira Yamamoto; Tsuneo Saga; Robert Tu ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 299 KB

## Abstract ## Purpose To investigate the T2\* values within the junctional zone and outer uterine myometrium and their changes during the menstrual cycle, and thus to evaluate their physiologic changes on blood oxygenation levelโ€dependent (BOLD) magnetic resonance (MR) imaging. ## Materials and

Evaluation of intraportal venous flow di
โœ Katsuyoshi Ito; Ayame Shimizu; Toshinobu Tsukuda; Katsumi Sasaki; Masahiro Tanab ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 414 KB

## Abstract ## Purpose To evaluate the efficacy of subtracted MR images from two sets of unenhanced threeโ€dimensional (3D) MR angiography data (tagโ€on and tagโ€off images) acquired simultaneously during a single breathโ€hold in assessing the intraportal venous flow distribution to the distal branche