## Abstract Contact‐angle goniometry confirms that interfacial energetics of protein adsorption to the hydrophobic solid/aqueous‐buffer (solid–liquid, SL) surface is not fundamentally different than adsorption to the aqueous‐buffer/air (liquid–vapor, LV) interface measured by pendant‐drop tensiomet
Scaled interfacial activity of proteins at the liquid-vapor interface
✍ Scribed by Krishnan, Anandi ;Sturgeon, Jacqueline ;Siedlecki, Christopher A. ;Vogler, Erwin A.
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 236 KB
- Volume
- 68A
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A principal conclusion drawn from observations of time‐ and concentration‐dependent liquid–vapor (LV) interfacial tension γ~lv~ of a diverse selection of proteins ranging from albumin to ubiquitin spanning nearly three decades in molecular weight (MW) is that concentration scaling substantially alters perception of protein interfacial activity as measured by reduction in γ~lv~. Proteins appear more similar than dissimilar on a weight/volume basis, whereas molarity scaling reveals a “Traube‐rule” ordering by MW, suggesting that adsorption is substantially driven by solution concentration rather than diversity in protein amphilicity. Scaling as a ratio‐to‐physiological‐concentration demonstrates that certain proteins exhibit the full possible range of interfacial activity at and well‐below physiological concentration, whereas others are only weakly surface active within this range, requiring substantially higher solution concentration to achieve reduction in γ~lv~. Important among this latter category of proteins are the blood factors XII and XIIa, assumed by the classical biochemical mechanism of plasma coagulation to adsorb to procoagulant surfaces, even in the presence of overwhelming concentrations of other blood constituents such as albumin and immunoglobulin that are shown by this work to be among the class of highly surface‐active proteins at physiologic concentration. A comparison of pendant drop and Wilhelmy balance tensiometry as tools for assessing protein interfacial activity shows that measurement conditions employed in the typical Wilhelmy plate approach fails to achieve the steady‐state adsorption condition that is accessible to pendant drop tensiometry. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 544–557, 2004
📜 SIMILAR VOLUMES
## Abstract For Abstract see ChemInform Abstract in Full Text.
tures of acetonitrile and hexane with ethanol or methanol While nonaqueous liquids are widely used commercially, the using the drop-volume method. Ross and Kornbrekke (4) interfacial chemistry of nonaqueous liquid/liquid systems has remeasured contact angles at a glass wall near the critical ceived
Polystyrene-b-poly(ethylene oxide) [P1503-SEO, M n : PS (2300) -PEO (3100), M w /M n : 1.08, PEO volume fraction: 0.56, calculated using known densities of polystyrene and poly(ethylene oxide) at room temperature (r PS = 1.05 g cm ±3 , r PEO = 1.13 g cm ±3 ) [11] Polymer Source, Inc.], liquid scint
## Abstract Molecular dynamics (MD) simulations are a vital tool in chemical research, as they are able to provide an atomistic view of chemical systems and processes that is not obtainable through experiment. However, large‐scale MD simulations require access to multicore clusters or supercomputer