โœฆ Synopsis


Certain kinds of artifacts have been reported when projection reconstruction (PR) techniques are used in magnetic resonance imaging (MRI). These will occur if the spacing between samples in k-space is too large. It has been suggested that PR requires finer k-space sampling than does two-dimensional Fourier reconstruction, and that the usual Nyquist criterion is inadequate. This paper examines this problem, with the conclusion that the Nyquist sampling criterion is adequate to avoid aliasing effects, provided that a band-limited interpolation is used in k-space. This procedure is motivated by analysis of the PR technique as it is commonly implemented in x-ray computed tomography. A related problem is shown to be the construction of a filter function in k-space that gives proper weight to the low spatial frequencies. It is shown that a simple ยฟkยฟ filter does not satisfy this requirement, and a procedure for deriving a suitable filter is described. The methods are tested in simulated PR profiles of circular disks of two different sizes. It is shown that the combination of the two new methods gives virtually perfect reconstruction for disks up to the size implied by the Nyquist limit.


๐Ÿ“œ SIMILAR VOLUMES


Consistent projection reconstruction (CP
โœ Gary H. Glover; Douglas C. Noll ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 744 KB

## Abstract Motion of the subject causes inconsistencies In MR scan data which in turn produce streaks in projection reconstruction (PR) scans or ghosts in 2DFT imaging. It is shown that a data manifold consistent with a static object may be extracted from input scan data by applying consistency cr

Centering the projection reconstruction
โœ Dana C. Peters; J. Andrew Derbyshire; Elliot R. McVeigh ๐Ÿ“‚ Article ๐Ÿ“… 2003 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 287 KB

## Abstract The projection reconstruction (PR) trajectory was investigated for the effect of gradient timing delays between the actual and requested start time of each physical gradient. Radial trajectories constructed with delayed gradients miss the center of __k__โ€space in an angularly dependent

Orthogonal projection sampling method us
โœ Yao Hongbing; Ye Xia; Zhou Jun; He Anzhi ๐Ÿ“‚ Article ๐Ÿ“… 2006 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 506 KB

## Abstract An orthogonal projection sampling method is proposed in this paper for the reconstruction of incomplete data field by using the prior knowledge algorithm based on the modified algebra reconstruction technology (ART) in the optical computerized tomography (OCT). Experiments based to this

Rapid tip tracking with MRI by a limited
โœ Kenji Shimizu; Robert V. Mulkern; Koichi Oshio; Lawrence P. Panych; Seung-Schik ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 499 KB

To rapidly track invasive devices within MRI systems, a novel approach using a limited projection reconstruction technique is presented. Our method exploits the difference between images reconstructed from a limited number of projections and serves to depict the tip of a needle during its advancemen