𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Safety and diagnostic accuracy of percutaneous ultrasound-guided biopsy of the spleen: A multicenter study

✍ Scribed by Mariano Gómez-Rubio; Antonio López-Cano; Paloma Rendón; Agustín Muñoz-Benvenuty; Manuel Macías; Carmen Garre; Jose María Segura-Cabral


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
121 KB
Volume
37
Category
Article
ISSN
0091-2751

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose.

To analyze the safety and accuracy of ultrasound‐guided (USG) percutaneous needle biopsy of the spleen.

Methods.

Sixty‐two USG needle biopsies performed in 52 patients were retrospectively analyzed: there were 53 biopsies of local lesions and 9 biopsies of diffuse lesions. Fine‐needle aspiration (FNA) was performed in 37 cases and core‐needle biopsy (CNB) in 25 cases. The complications and diagnostic accuracy of the 2 types of biopsy were compared.

Results.

Two patients (3.8%) had postprocedural hemorrhage after CNB; one was minor, and the other severe, requiring splenectomy. No bleeding occurred with FNA. The diagnostic accuracy was similar with FNA (86.5%) and CNB (92%), whereas in patients with lymphoma, accuracy of FNA (80%) tended to be lower than that of CNB (100%), although the difference was not statistically significant.

Conclusion.

USG needle biopsy is safe and effective for diagnosing both focal and diffuse splenic lesions. The risk of bleeding may be lower with FNA than with CNB. © 2009 Wiley Periodicals, Inc. J Clin Ultrasound, 2009


📜 SIMILAR VOLUMES


Ultrasound-guided biopsy of the thyroid:
✍ Karen E. Schoedel; Mitchell E. Tublin; Karen Pealer; N. Paul Ohori 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 55 KB

## Abstract Ultrasound‐guided sampling of the thyroid represents a standard diagnostic procedure in the evaluation of thyroid nodules. The two techniques typically used are fine‐needle aspiration and fine‐needle capillary biopsy. Each has been used with success in various body sites. Recently, a co

Radiologically guided percutaneous fine-
✍ Ziwen Guo; Daniel F.I. Kurtycz; Riad Salem; Luis E. De Las Casas; James G. Caya; 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 384 KB 👁 1 views

## Abstract We reviewed 119 percutaneous, radiologically guided fine‐needle aspirations (FNA) from 114 patients with liver masses to evaluate diagnostic effectiveness and complications of this procedure. Satisfactory material was obtained in 118 cases (99%), of which 78 were diagnosed as positive (

Diagnostic accuracy of stereotactic larg
✍ Helena M. Verkooijen 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 French ⚖ 93 KB 👁 1 views

## Abstract Stereotactic large‐core needle biopsy is increasingly applied for the diagnosis of nonpalpable breast disease. Our study examines whether this minimally invasive technique is sufficiently accurate to replace surgical breast biopsy. In a prospective multicenter study, 973 consecutive wom

Ultrasound-guided lumpectomy of nonpalpa
✍ Rahusen, Frans D.; van Amerongen, Annette H. M. Taets; van Diest, Paul J.; Borgs 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 109 KB 👁 1 views

Background and Objectives: Complete excision of a nonpalpable breast cancer after wire localization is a difficult procedure. Often, adequate margins are not obtained, and a second procedure is then required. Prospectively, we studied the feasibility of ultrasound-guided excisions of nonpalpable bre