๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Safe parameters for laser chondroplasty of the knee

โœ Scribed by Janecki, Chet J.; Perry, Michael W.; Bonati, Alfred O.; Bendel, Michelle


Book ID
102646160
Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
678 KB
Volume
23
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

โœฆ Synopsis


Background and objective:

The purpose of this study is to summarize our use of the holmium laser as a tool in performing chondroplasties of the knee and to determine whether any untoward affects developed at the site of laser application.

Study design/materials and methods:

A retrospective review of 504 laser chondroplasties of the medial femoral condyle was done. laser parameters and the average number of joules to perform the chondroplasties were recorded. the average follow-up was 11 months.

Results:

Preoperative mri interpretation indicated that 8% of the patients had osteonecrosis prior to surgery. 88% of the patients were satisfied with the procedure. all failures were evaluated by x-ray, mri, bone scan, or biopsy of the medial femoral condyle. no new cases of osteonecrosis were determined.

Conclusion:

No new cases of osteonecrosis were documented of the medial femoral condyle following laser chondroplasty utilizing the parameters in this study. the holmium laser remains a safe and efficacious tool in performing chondroplasty.