✦ LIBER ✦
Routine resite of peripheral intravenous devices every 3 days did not reduce complications compared with clinically indicated resite: a randomised controlled trial
✍ Scribed by Claire M Rickard; Damhnat McCann; Jane Munnings; Matthew R McGrail
- Book ID
- 115022082
- Publisher
- BioMed Central
- Year
- 2010
- Tongue
- English
- Weight
- 431 KB
- Volume
- 8
- Category
- Article
- ISSN
- 1741-7015