Routine production and quality control of 123I-labelled mIBG at NAC
✍ Scribed by D. Du T. Rossouw
- Publisher
- Elsevier Science
- Year
- 1992
- Weight
- 152 KB
- Volume
- 43
- Category
- Article
- ISSN
- 0883-2889
No coin nor oath required. For personal study only.
✦ Synopsis
An existing method, developed in our laboratory, has been further improved for the large scale routine production of [mI]mlBG. Losses of 1231 during production have been decreased from 16% to <3% and labelling efficiencies of >98% are now consistently obtained. A sensitive HPLC quality control method for p23I]mlBG, based on reversephase ion-pair chromatography, has also been developed.
📜 SIMILAR VOLUMES
## Abstract Two anti‐osteosarcoma monoclonal antibodies (TP‐3 IgG and TP‐1 F(ab′)~2~) were labelled with the α‐particle emitting radionuclide ^211^At and, for comparison of stability, with ^125^I using the N‐succinimidyl‐3‐(trimethylstannyl)benzoate intermediate. The quality of the final preparatio