𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Routine intraoperative Doppler sonography in the evaluation of complications after living-related donor liver transplantation

✍ Scribed by Jin-Young Choi; Jae Young Lee; Jeong Min Lee; Se Hyung Kim; Min Woo Lee; Joon Koo Han; Byung Ihn Choi


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
322 KB
Volume
35
Category
Article
ISSN
0091-2751

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To determine whether quantitative and qualitative analysis of intraoperative Doppler sonography data are predictive of vascular complications after living‐related donor liver transplantation.

Methods

Intraoperative sonograms of 81 transplanted livers (right lobe in 61 patients, left lobe in 20 patients) were analyzed for the presence of blood flow, resistance index, systolic acceleration time (SAT), peak systolic velocity, and morphologic characteristics of spectral waveform of the hepatic artery. Peak velocity and spectral waveforms of portal and hepatic veins were also analyzed. Intraoperative sonography results were compared with information obtained with multidetector‐row CT (MDCT) angiography or conventional angiography. The time interval between operation and angiography ranged from 1 to 23 days (mean, 8.5 days).

Results

Hepatic artery stenosis (HAS) was identified in 20 patients via MDCT angiography, conventional angiography, or both. The Doppler parameters found helpful for predicting HAS were tardus‐parvus pattern and delayed SAT. The sensitivity, specificity, and negative predictive value (NPV) were 60.0%, 73.7%, and 84.9%, respectively, for tardus‐parvus pattern and 40.0%, 83.6%, and 80.9%, respectively, for delayed SAT. Peak velocities of the portal and hepatic veins were not reliable indicators of vascular complication. Loss of triphasity of the hepatic vein had a 98.4% NPV for venous obstruction.

Conclusions

Delayed SAT of the hepatic artery and loss of triphasity of the hepatic vein had a >80% for specificity for predicting vascular complications. Tardus‐parvus pattern, delayed SAT of the hepatic artery, and loss of triphasity of the hepatic vein showed an acceptable NPV for identifying vascular complications. © 2007 Wiley Periodicals, Inc. J Clin Ultrasound, 2007


📜 SIMILAR VOLUMES


“Hepar divisum”– as a rare donor complic
✍ Silvio Nadalin; Massimo Malagó; Giuliano Testa; Randolph Schaffer; Georgios C. S 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 101 KB

In this study, we present our experience with 4 healthy donors having the rare condition of "hepar divisum" after the intraoperative death of the recipient of an intended right adult living donor liver transplantation (LDLT). The study included 4 donors and 4 intended right LDLT recipients affected

Evaluation of the hepatic artery anastom
✍ Han Song Mun; Kyoung Won Kim; Gi-Won Song; Chul-Soo Ahn; So Yeon Kim; Shin Hwang 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 292 KB 👁 1 views

## Abstract ## Objective To describe the usefulness of intraoperative ultrasonography (IOUS) with high‐frequency transducer in living donor liver transplantation (LDLT) using right‐lobe graft (RLG). ## Method This retrospective study was approved by our institutional review board. We performed I

Experience after the evaluation of 700 p
✍ Camino Valentín-Gamazo; Massimo Malagó; Marc Karliova; Juergen T. Lutz; Andrea F 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 153 KB 👁 2 views

Adequate selection of donors is a major prerequisite for living donor liver transplantation (LDLT). Few centers report on the entire number of potential donors considered or rejected for living donation. From April 1998 to July 2003, a total of 111 living donor liver transplantations were performed

W-shaped diastolic Doppler waveform in t
✍ Hiroyuki Sugimoto; Tetsuya Kiuchi; Akimasa Nakao 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 188 KB 👁 1 views

## Abstract Waveform analysis of arterial Doppler sonography signals is widely used in clinical practice. A characteristic, W‐shaped diastolic waveform has been reported in the renal artery of renal transplant recipients in cases of renal vein thrombosis or severe acute rejection. Although Doppler