## Abstract The long readout times of single‐shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level‐dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction,
Robust field map generation using a triple-echo acquisition
✍ Scribed by Christian Windischberger; Simon Robinson; Alexander Rauscher; Markus Barth; Ewald Moser
- Book ID
- 102374975
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 313 KB
- Volume
- 20
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To establish a fast and robust technique for generating magnetic field maps for the correction of geometric distortions in echo‐planar magnetic resonance (MR) images.
Materials and Methods
Multislice gradient‐echo (GE) images were acquired at echo times of 6, 6.5, and 7.5 msec in order to cover a field shift range of ±666 Hz in the resulting B~0~ maps. To account for possible phase wrap scenarios, seven phase triples were calculated for each pixel. Linear regression of the phase vs. echo time was performed for each set. The slope of the set with the minimum fitting error was taken as the true magnetic field in the respective pixel.
Results
Based on the fitting error distribution, the technique is shown to be feasible and effective for assessing the field distribution in the brain at 3 T, especially in inferior brain areas (amygdalae, hippocampus). Examples of echo‐planar images distortion corrected using the calculated field maps are shown.
Conclusion
The approach presented yields robust estimation of magnetic field maps and requires under a minute of additional acquisition time and only seconds of computational time. As such, it is easily possible to apply image distortion correction in routine functional MR imaging (fMRI) studies, enabling improved coregistration of brain activation maps with structures on anatomical images. J. Magn. Reson. Imaging 2004;20:730–734. © 2004 Wiley‐Liss, Inc.