𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Retrospective motion correction protocol for high-resolution anatomical MRI

✍ Scribed by Peter Kochunov; Jack L. Lancaster; David C. Glahn; David Purdy; Angela R. Laird; Feng Gao; Peter Fox


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
169 KB
Volume
27
Category
Article
ISSN
1065-9471

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Modern computational brain morphology methods require that anatomical images be acquired at high resolution and with a high signal‐to‐noise ratio. This often translates into long acquisition times (>20 minutes) and images susceptible to head motion. In this study we tested retrospective motion correction (RMC), common for functional MRI (fMRI) and PET image motion correction, as a means to improve the quality of high‐resolution 3‐D anatomical MR images. RMC methods are known to be effective for correcting interscan motion; therefore, a single high‐resolution 3‐D MRI brain study was divided into six shorter acquisition segments to help shift intrascan motion into interscan motion. To help reduce intrascan head motion, each segment image was reviewed for motion artifacts and repeated if necessary. Interscan motion correction was done by spatially registering images to the third image and forming a single average motion‐corrected image. RMC was tested on 35 subjects who were considered at high risk for head motion. Our results show that RMC provided better contrast‐to‐noise ratio and boundary detail when compared to nonmotion‐corrected averaged images. Hum Brain Mapp, 2006. © 2006 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Real-time motion correction for high-res
✍ Joëlle K. Barral; Juan M. Santos; Edward J. Damrose; Nancy J. Fischbein; Dwight 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 451 KB

## Abstract Motion—both rigid‐body and nonrigid—is the main limitation to in vivo, high‐resolution larynx imaging. In this work, a new real‐time motion compensation algorithm is introduced. Navigator data are processed in real time to compute the displacement information, and projections are correc

High spatial and temporal resolution car
✍ Peter Kellman; Christophe Chefd'hotel; Christine H. Lorenz; Christine Mancini; A 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 871 KB

## Abstract Cine MRI is used for assessing cardiac function and flow and is typically based on a breath‐held, segmented data acquisition. Breath holding is particularly difficult for patients with congestive heart failure or in pediatric cases. Real‐time imaging may be used without breath holding o

Quantitative assessment of motion correc
✍ Ken E. Sakaie; Mark J. Lowe 📂 Article 📅 2010 🏛 Elsevier Science 🌐 English ⚖ 851 KB

Several methods have been proposed for motion correction of high angular resolution diffusion imaging (HARDI) data. There have been few comparisons of these methods, partly due to a lack of quantitative metrics of performance. We compare two motion correction strategies using two figures of merit: d

Validation of simple and robust protocol
✍ Magdalena Zurek; Amine Bessaad; Katarzyna Cieslar; Yannick Crémillieux 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 388 KB

## Abstract One fundamental limitation of spatial resolution for in vivo MR lung imaging is related to motion in the thoracic cavity. To overcome this limitation, several methods have been proposed, including scan‐synchronous ventilation and the cardiac gating approach. However, with cardiac and ve

Noninvasive detection of coronary artery
✍ Andrew D. Scott; Jennifer Keegan; Raad H. Mohiaddin; David N. Firmin 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 535 KB

## Abstract ## Purpose: To demonstrate coronary artery wall thickening with age in a small healthy cohort using a highly efficient, reliable, and reproducible high‐resolution MR technique. ## Materials and Methods: A 3D cross‐sectional MR vessel wall images (0.7 × 0.7 × 3 mm resolution) with ret