Restricted field of view magnetic resonance imaging of a dynamic time series

✍ Scribed by Laura Pisani; Roland Bammer; Gary Glover


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
957 KB
Volume
57
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A restricted field of view (rFOV) approach for imaging a dynamic time series of volumes of limited spatial extent within a larger subject is described. The shorter readout with rFOV‐MRI can be exploited to either limit image artifacts or increase spatial resolution. To accomplish rFOV imaging of a multislice volume for a dynamic series, an outer volume suppression (OVS) preparation that saturates signal external to a cylinder through the subject is followed by slice‐selective excitation and a spiral readout. The pass‐ and stopband efficiencies of the OVS in an agar gel phantom were 97% (±1.5%) and 3% (±1%), respectively. Profiles of the temporal signal‐to‐noise ratio (SNR) were measured in a phantom and an adult brain. The rFOV sequence reduced distortions from off‐resonance signal and T‐induced blurring compared to a conventional sequence. Sequence utility is demonstrated for high‐resolution rFOV functional MRI (fMRI) in the visual cortex. The rFOV sequence may prove to be useful for other multislice dynamic and high‐resolution imaging applications. Magn Reson Med 57:297–307, 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Reduced field of view and undersampled P
✍ Dana C. Peters; Michael A. Guttman; Alexander J. Dick; Venkatesh K. Raman; Rober 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 931 KB

## Abstract Active catheter imaging was investigated using real‐time undersampled projection reconstruction (PR) combined with the temporal filtering technique of reduced field of view (rFOV). Real‐time rFOV processing was interactively enabled during highly undersampled catheter imaging, resulting

Variable field of view for spatial resol
✍ Houchun H. Hu; Ananth J. Madhuranthakam; David G. Kruger; James F. Glockner; Ste 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 475 KB

## Abstract An approach is described in which the field of view (FOV) along the __Y__ (right/left) phase encoding direction can be dynamically altered during a continuously moving table (CMT) coronal acquisition for extended FOV MRI. We hypothesize that with this method, regions of the anatomy exhi

Implementation of a reduced field-of-vie
✍ Walid E. Kyriakos; Lawrence P. Panych; Gary P. Zientara; Ferenc A. Jolesz 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 1019 KB

## Abstract A new technique was designed and implemented that increases imaging speed in dynamic imaging in which change is restricted to a fraction of the full field of view (FOV). The technique is an enhancement of a reduced FOV method first reported by Hu and Parrish. This enhancement extends th